Hand-Held Personal Digital Assistant Program for the HEMOCHRONregistered RxDxregistered Heparin and Protamine Dosing System

نویسندگان

  • Soumaya El Rouby
  • Kristin Rinehart
  • Marcia L. Zucker
  • Frank M. LaDuca
چکیده

The use of in vitro dosing assays for heparin and protamine during cardiac surgery has significantly improved overall postoperative patient outcome. The HEMOCHRON RxDx system (International Technidyne Corp, Edison, NJ) is widely used for anticoagulation management. Based on a series of consecutive in vitro tests, the RxDx system is used to quantify the patient’s heparin requirement (heparin response test, HRT), measure the activated clotting time (ACT), calculate the blood heparin concentration and the required protamine dose (protamine response test, PRT), as well as determine the efficacy of heparin reversal (protamine dose assay, PDA-O). A hand-held personal digital assistant (PDA) program has been developed that performs the RxDx calculations used for anticoagulation management during cardiac surgery. The PalmTM m505 handheld device (Palm, Inc., Santa Clara, CA) is used in concert with any standard Hemochron blood coagulation system. The Palm m505 device has been programmed to perform all the calculations required for the RxDx test system. Patient’s body weight, height, and gender are entered into the program using the onscreen keypad and the template provided in the Hemochron program. The calculator automatically provides the patient’s blood volume and the recommended heparin dose upon entering the baseline ACT and HRT values and a target ACT. At the end of the case, the optimal protamine dose is determined, and the total heparin level is calculated and displayed upon entry of ACT and PRT clotting times. Following protamine administration, the program calculates any additional protamine required to neutralize residual heparin using the data from a PDA-O test. The RxDx hand-held PDA is accurate, quick, simple, and easy to use, patient data are saved and can be retrieved. The inclusion of this rapid computing technology into the Hemochron RxDx system serves to expand the applications of the Hemochron RxDx system during cardiac interventions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Hemochron Response RxDx heparin and protamine dosing system.

The use of dosing assays to calculate heparin and protamine dose requirements during cardiac surgery has been shown to significantly improve overall postoperative patient outcome. When patients are managed with an individualized dosing system, intraoperative and postoperative transfusion requirements and bleeding are reduced. The Hemochron RxDx system is widely used as a complement to tradition...

متن کامل

Utility of In Vitro Heparin and Protamine Titration for Dosing During Cardiopulmonary Bypass Surgery

Methods used to maintain a hemostatic balance during cardiopulmonary bypass surgery include the optimization of heparin and protamine dosing. Higher heparin doses have been associated with increased bleeding, while other studies have attributed reduced blood loss and transfusion requirements to lower protamine doses. We have evaluated the use of an in vitro heparin and protamine titration syste...

متن کامل

A four-year experience with patient individualized heparin and protamine dosing using the Hemochron RxDx system.

Cardiac surgical case histories, collected over 4 years at Huntsville Hospital in Alabama, were reviewed for 2,293 patients. Patients were separated into two dosing groups for both heparin and protamine, hospital empirically dosed and Hemochron RxDx dosed. Review of the heparin dosing information found that incomplete data were collected for 47 patients, leaving 2,246 patients eligible to be ev...

متن کامل

Integrating a Hand Held computer and Stethoscope into a Fetal Monitor

This article presents procedures for modifying a hand held computer or personal digital assistant (PDA) into a versatile device functioning as an electronic stethoscope for fetal monitoring. Along with functioning as an electronic stethoscope, a PDA can provide a useful information source for a medical trainee. Feedback from medical students, residents and interns suggests the device is well ac...

متن کامل

Low Molecular Weight Heparin Overdose: A 10 Year Case Series

  Background: Low molecular weight heparin (LMWH) is used for the treatment and prevention of coagulative disorders. Few patients receiving therapeutic doses of LMWH develop major hemorrhage. Currently there are few reports in the literature on acute overdose on adults.  In this study, clinical profile, treatment and outcome of 21 patients who acutely overdosed enoxaparin are described. Method...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003