Intra- and inter-rater reliability of isometric shoulder extensor and internal rotator strength measurements performed using a hand-held dynamometer

نویسندگان

  • Takenori Awatani
  • Ikuhiro Morikita
  • Junji Shinohara
  • Seigo Mori
  • Miki Nariai
  • Yasutaka Tatsumi
  • Akinori Nagata
  • Hiroya Koshiba
چکیده

[Purpose] The purpose of the present study was to establish the intra- and inter-rater reliability of measurement of extensor strength in the maximum shoulder abducted position and internal rotator strength in the 90° abducted and the 90° external rotated position using a hand-held dynamometer. [Subjects and Methods] Twelve healthy volunteers (12 male; mean ± SD: age 19.0 ± 1.1 years) participated in the study. The examiners were two students who had nonclinical experience with a hand-held dynamometer measurement. The examiners and participants were blinded to measurement results by the recorder. Participants in the prone position were instructed to hold the contraction against the ground reaction force, and peak isometric force was recorded using the hand-held dynamometer on the floor. Reliability was determined using intraclass correlation coefficients. [Results] The intra- and inter-rater reliability data were found to be "almost perfect". [Conclusion] This study investigated intra- and inter-rater reliability and reveald high reliability. Thus, the measurement method used in the present study can evaluate muscle strength by a simple measurement technique.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Same-session and between-day intra-rater reliability of hand-held dynamometer measurements of isometric shoulder extensor strength.

[Purpose] The purpose of present study was to establish the same-session and between-day intra-rater reliability of measurements of extensor strength in the maximum abducted position (MABP) using hand-held dynamometer (HHD). [Subjects] Thirteen healthy volunteers (10 male, 3 female; mean ± SD: age 19.8 ± 0.8 y) participated in the study. [Methods] Participants in the prone position with maximum...

متن کامل

Intra- and Inter-Rater Reliability of Micro Manual Muscle Tester of the Lower Extremity in Children With Diplegia Cerebral Palsy

Objectives: The Micro Manual Muscle Tester (MMMT) is a Hand-Held Dynamometer (HHD). The current study aimed to evaluate the intra- and inter-rater reliability of this device. Methods: To determine the reliability of the MMMT, two previously trained assessors to work with HHD performed HHD measurements on 7 muscle groups of the lower extremities (hip flexors, hip extensors, hip abductors, knee ...

متن کامل

Measuring shoulder external and internal rotation strength and range of motion: comprehensive intra-rater and inter-rater reliability study of several testing protocols.

BACKGROUND Shoulder range of motion (ROM) and strength measurements are imperative in the clinical assessment of the patient's status and progression over time. The method and type of assessment varies among clinicians and institutions. No comprehensive study to date has examined the reliability of a variety of procedures based on different testing equipment and specific patient or shoulder pos...

متن کامل

Reliability of measurements of knee extensor muscle strength using a pull-type hand-held dynamometer

[Purpose] The purpose of this study was to examine the intra-examiner and inter-examiner reliabilities of measurements of knee extensor muscle strength using a pull-type hand-held dynamometer (HHD). [Subjects] Fifty-four healthy adults (35 males; average age, 23 years) participated in this study. [Methods] Knee extensor muscle strength of each leg was measured three times using the HHD. To exam...

متن کامل

Enhancing the examiner's resisting force improves the reliability of manual muscle strength measurements: comparison of a new device with hand-held dynamometry.

OBJECTIVE To develop and determine the reliability of a newly -designed resistance-enhanced dynamometer for muscle strength measurement, and to test the hypothesis that enhancing the examiner's resisting force improves the reliability of manual muscle strength measurements. DESIGN An intra-examiner, inter-examiner, intra-session and inter-session reliability study. SUBJECTS Twenty-five men ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 28  شماره 

صفحات  -

تاریخ انتشار 2016