Wide-Angle Viewing System versus Conventional Indirect Ophthalmoscopy for Scleral Buckling
نویسندگان
چکیده
Wide-angle viewing systems (WAVSs) were originally established for pars plana vitrectomy. However, their application to scleral buckling surgery was recently reported. In this study, we compared the outcomes of scleral buckling using a noncontact WAVS with that of scleral buckling using conventional indirect ophthalmoscopy for rhegmatogenous retinal detachment. The clinical records of 39 eyes (39 patients) with rhegmatogenous retinal detachment primarily treated between November 2012 and June 2014 at the Vitreo-Retina Surgical Division Clinic at the Department of Ophthalmology, Keio University Hospital were retrospectively reviewed. Scleral bucking was performed using WAVS with surgical placement of an endoilluminator in 16 eyes and indirect ophthalmoscopy in 23 eyes. The patients in these groups were consecutive over different intervals. The preoperative demographics, success rate of retinal reattachment, intraoperative findings, and postoperative complications were evaluated. There were no significant differences in pre- or postoperative conditions between groups, and similar surgical outcomes were achieved with the WAVS and conventional procedures. However, compared with the conventional procedure, the WAVS procedure resulted in fewer intraoperative corneal epithelial disorders (p = 0.049) and decreased the surgical duration of segmental buckling (p = 0.02); therefore, it may be suggested as an effective alternative procedure.
منابع مشابه
Scleral buckling for primary rhegmatogenous retinal detachment using noncontact wide-angle viewing system with a cannula-based 25 G chandelier endoilluminator
PURPOSE To assess the outcome of scleral buckling surgery using a noncontact wide-angle viewing system for fundus visualization in patients with rhegmatogenous retinal detachment. METHODS Twenty-eight eyes of 28 patients underwent a modified scleral buckling surgery using a noncontact wide-angle viewing system combined with a 27-gauge optic fiber inserted into the sclera at the pars plana thr...
متن کاملScleral Buckling Using a Non-contact Wide-Angle Viewing System with a 25-Gauge Chandelier Endoilluminator
PURPOSE To report the outcome of scleral buckling using a non-contact wide-angle viewing system with a 25-gauge chandelier endoilluminator. METHODS Retrospective analyses of medical records were performed for 17 eyes of 16 patients with primary rhegmatogenous retinal detachment (RRD) without proliferative vitreoretinopathy who had undergone conventional scleral buckling with cryoretinopexy us...
متن کاملScleral buckling with a noncontact wide-angle viewing system in the management of retinal detachment with undetected retinal break: a case report
A young patient who showed rhegmatogenous retinal detachment with preoperatively undetected retinal break was successfully treated by scleral buckling using a noncontact wide-angle viewing system.
متن کاملControversies in Vitreoretinal Surgery: is Scleral buckling an important Mainstay in the treatment of retinal detachment in 2014? Scleral Buckle for Retinal Detachment: Pro
By Gaurav K. Shah, MD; and Baseer Ahmad, MD Is scleral buckling surgery for retinal detachment (RD) repair here to stay? We believe the answer is “yes,” but only if ophthalmologists continue to perform and teach these procedures. If we do not, scleral buckling procedures will pass into history. There is no doubt that pars plana vitrectomy (PPV) is an effective procedure, valued day in and day o...
متن کاملScleral Buckling with Chandelier Illumination
Scleral buckling is a highly successful technique for the repair of rhegmatogenous retinal detachment that requires intra-operative examination of the retina and treatment of retinal breaks via indirect ophthalmoscopy. Data suggest that scleral buckling likely results in improved outcomes for many patients but is declining in popularity, perhaps because of significant advances in vitrectomy ins...
متن کامل