Time course of endothelium-dependent and -independent coronary vasomotor response to coronary balloons and stents. Comparison of plain and drug-eluting balloons and stents.

نویسندگان

  • Christian A Plass
  • Inna Sabdyusheva-Litschauer
  • Andreas Bernhart
  • Eslam Samaha
  • Ors Petnehazy
  • Eszter Szentirmai
  • Zsolt Petrási
  • Victor Lamin
  • Noemi Pavo
  • Noemi Nyolczas
  • András Jakab
  • Zsolt Murlasits
  • Jutta Bergler-Klein
  • Gerald Maurer
  • Mariann Gyöngyösi
چکیده

OBJECTIVES This study sought to determine the time dependency of the endothelium-dependent and -independent vascular responses after percutaneous coronary intervention (PCI) with drug-eluting (DEB) or plain balloons, bare-metal (BMS), and drug-eluting (DES) stents, or controls. BACKGROUND Long-term endothelial dysfunction after DES implantation is associated with delayed healing and late thrombosis. METHODS Domestic pigs underwent PCI using DEB or plain balloon, BMS, or DES. The dilated and stented segments, and the proximal reference segments of stents and control arteries were explanted at 5-h, 24-h, 1-week, and 1-month follow-up (FUP). Endothelin-induced vasoconstriction and endothelium-dependent and -independent vasodilation of the arterial segments were determined in vitro and were related to histological results. RESULTS DES- and BMS-treated arteries showed proneness to vasoconstriction 5 h post-PCI. The endothelium-dependent vasodilation was profoundly (p < 0.05) impaired early after PCI (9.8 ± 3.7%, 13.4 ± 9.2%, 5.7 ± 5.3%, and 7.6 ± 4.7% using plain balloon, DEB, BMS, and DES, respectively), as compared with controls (49.6 ± 9.5%), with slow recovery. In contrast to DES, the endothelium-related vasodilation of vessels treated with plain balloon, DEB, and BMS was increased at 1 month, suggesting enhanced endogenous nitric oxide production of the neointima. The endothelium-independent (vascular smooth muscle-related) vasodilation decreased significantly at 1 day, with slow normalization during FUP. All PCI-treated vessels exhibited imbalance between vasoconstriction-vasodilation, which was more pronounced in DES- and BMS-treated vessels. No correlation between histological parameters and vasomotor function was found, indicating complex interactions between the healing neoendothelium and smooth muscle post-PCI. CONCLUSIONS Coronary arteries treated with plain balloon, DEB, BMS, and DES showed time-dependent loss of endothelial-dependent and -independent vasomotor function, with imbalanced contraction/dilation capacity.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An advection-diffusion multi-layer porous model for stent drug delivery in coronary arteries

Arterial drug concentration distribution determines local toxicity. The safety issues dealt with Drug-Eluting Stents (DESs) reveal the needs for investigation about the effective factors contributing to fluctuations in arterial drug uptake. The current study focused on the importance of hypertension as an important and controversial risk factor among researchers on the efficacy of Heparin-Eluti...

متن کامل

Treatment strategies for coronary in-stent restenosis: systematic review and hierarchical Bayesian network meta-analysis of 24 randomised trials and 4880 patients

STUDY QUESTION What is the most safe and effective interventional treatment for coronary in-stent restenosis? METHODS In a hierarchical Bayesian network meta-analysis, PubMed, Embase, Scopus, Cochrane Library, Web of Science, ScienceDirect, and major scientific websites were screened up to 10 August 2015. Randomised controlled trials of patients with any type of coronary in-stent restenosis (...

متن کامل

Paclitaxel balloon coating, a novel method for prevention and therapy of restenosis.

BACKGROUND Drug-eluting stents have shown promising antirestenotic effects in clinical trials. Non-stent-based local delivery of antiproliferative drugs may offer additional flexibility and also reach vessel areas beyond the immediate stent coverage. The aim of the present study was to evaluate a novel method of local drug delivery based on angioplasty balloons. METHODS AND RESULTS Stainless ...

متن کامل

Interference of drug-eluting stents with endothelium-dependent coronary vasomotion: evidence for device-specific responses.

BACKGROUND There is evidence that endothelial coverage of drug-eluting stents might be delayed or absent, a risk factor for late thrombotic events. We studied the effects of different drug-polymer-device iterations on endothelium-dependent coronary vasomotion. Systemic markers of endothelial inflammation were correlated with coronary vasomotor changes. METHODS AND RESULTS Patients with paclit...

متن کامل

Particle release from drug eluting balloons and stents - simulated use testing.

Particles released in the coronary arteries or a carotid artery during interventions such as percutaneous transluminal coronary angioplasty (ptca) can cause complications such as occlusions of small vessels or capillaries, leading to micro embolisations and increasing the risk of the no-reflow phenomenon. The aim is to develop and implement simulated use testing methods and to analyse mechanism...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • JACC. Cardiovascular interventions

دوره 5 7  شماره 

صفحات  -

تاریخ انتشار 2012