Ultra-stable clock laser system development towards space applications
نویسندگان
چکیده
The increasing performance of optical lattice clocks has made them attractive for scientific applications in space and thus has pushed the development of their components including the interrogation lasers of the clock transitions towards being suitable for space, which amongst others requires making them more power efficient, radiation hardened, smaller, lighter as well as more mechanically stable. Here we present the development towards a space-compatible interrogation laser system for a strontium lattice clock constructed within the Space Optical Clock (SOC2) project where we have concentrated on mechanical rigidity and size. The laser reaches a fractional frequency instability of 7.9 × 10-16 at 300 ms averaging time. The laser system uses a single extended cavity diode laser that gives enough power for interrogating the atoms, frequency comparison by a frequency comb and diagnostics. It includes fibre link stabilisation to the atomic package and to the comb. The optics module containing the laser has dimensions 60 × 45 × 8 cm3; and the ultra-stable reference cavity used for frequency stabilisation with its vacuum system takes 30 × 30 × 30 cm3. The acceleration sensitivities in three orthogonal directions of the cavity are 3.6 × 10-10/g, 5.8 × 10-10/g and 3.1 × 10-10/g, where g ≈ 9.8 m/s2 is the standard gravitational acceleration.
منابع مشابه
Fundamental Architecture and Performance Analysis of Photofission Pulsed Space Propulsion System Using Ultra-Intense Laser
Photofission enables a unique capability for the domain of non-chemical space propulsion. An ultra-intense laser enables the capacity to induce nuclear fission through the development of bremsstrahlung photons. A fundamental architecture and performance analysis of a photofission pulsed space propulsion system through the operation of an ultra-intense laser is presented. A historical perspectiv...
متن کاملProspects for Ultra-stable Timekeeping with Sealed Vacuum Operation in Multi-pole Linear Ion Trap Standards
A recent long-term comparison between the compensated multi-pole Linear Ion Trap Standard (LITS) and the laser-cooled primary standards via GPS carrier-phase time transfer showed a deviation of less than 2.7×10/day. A subsequent evaluation of potential drift contributors in the LITS showed that the leading candidates are fluctuations in background gases and the neon buffer gas. The current vacu...
متن کاملCold Atom Clocks and Applications
This paper describes advances in microwave frequency standards using laser-cooled atoms at BNM-SYRTE. First, recent improvements of the 133 Cs and 87 Rb atomic fountains are described. Thanks to the routine use of a cryogenic sapphire oscillator as an ultra-stable local frequency reference, a fountain frequency instability of 1.6 × 10 −14 τ −1/2 where τ is the measurement time in seconds is mea...
متن کاملFrequency-stabilised Laser Reference System for Trace-gas Sensing Applications from Space
A four-wavelength low-power continuous-wave frequency laser reference system has been realised in the 935.4-nm range for water vapour differential absorption lidar (DIAL) applications. The system is built around laboratory extended-cavity and DFB diode lasers. Three lasers are directly locked to three water vapour absorption lines of different strength, whereas the wavelength of the fourth lase...
متن کاملHigh-power femtosecond Yb-doped single-polarization photonic crystal fiber laser
We report, to the first time to our knowledge, on a passively mode-locked single-polarization single-transverse-mode large-mode-area photonic crystal fiber laser operating in the dispersion compensation free regime. In the single-pulse regime, the laser generates 1.6 W of average power with 3.7 ps pulses at a repetition rate of 63 MHz, corresponding to a pulse energy of 25 nJ. Stable and self-s...
متن کامل