An Effective Technique for Enhancing an Intrauterine Catheter Fetal Electrocardiogram
نویسندگان
چکیده
Physicians can obtain fetal heart rate, electrophysiological information, and uterine contraction activity for determining fetal status from an intrauterine catheters electrocardiogram with the maternal electrocardiogram canceled. In addition, the intrauterine catheter would allow physicians to acquire fetal status with one noninvasive to the fetus biosensor as compared to invasive to the fetus scalp electrode and intrauterine pressure catheter used currently. A real-time maternal electrocardiogram cancellation technique of the intrauterine catheters electrocardiogram will be discussed along with an analysis for the methods effectiveness with synthesized and clinical data. The positive results from an original detailed subjective and objective analysis of synthesized and clinical data clearly indicate that the maternal electrocardiogram cancellation method was found to be effective. The resulting intrauterine catheters electrocardiogram from effectively canceling the maternal electrocardiogram could be used for determining fetal heart rate, fetal electrocardiogram electrophysiological information, and uterine contraction activity.
منابع مشابه
Pnm-1: Applications of Hysterosonography for The Detection of Intracavitary Uterine Abnormalities
Hysterosonography (SHG) is a new noninvasive technique that involves the slow infusion of sterile saline solution into the uterus during ultrasound imaging. Expansion of endometrial cavity by SHG allows optimal visualization and plays an important role in the evaluation of abnormalities related to the uterus. The most common indications for hysterosonography are: abnormal uterine bleeding both ...
متن کاملComplications Associated with Insertion of Intrauterine Pressure Catheters: An Unusual Case of Uterine Hypertonicity and Uterine Perforation Resulting in Fetal Distress after Insertion of an Intrauterine Pressure Catheter
Insertion of intrauterine pressure catheters is a routine procedure performed in labor and delivery departments, with few associated complications. There are several reports of maternal and neonatal morbidity associated with the use of intrauterine pressure catheters and their rare adverse outcomes. We report an unusual case of uterine hypertonicity resulting in fetal distress, immediately afte...
متن کاملبررسی عوامل خطرزای مرگ داخل رحمی جنین در زنان مراجعه کننده به مراکز بهداشتی درمانی دانشگاه علوم پزشکی ایران(تهران، سالهای 1376 تا 1380)
The aim of this study was to identify risk factors of intrauterine fetal death. A retrospective analysis was conducted on 1288 stillbirth as case and 3888 live birth as control subjects, from first of March 1997 to the end of February 2001. Intrauterine fetal death was defined by an estimated gestational age more than 20 weeks, or fetal weight more than 500gm. The goal of the presen...
متن کاملIntrauterine Pressure Catheter
An intrauterine pressure catheter (IUPC) is a device placed inside a pregnant woman?s uterus [2] to monitor uterine contractions during labor. During labor, a woman?s uterus [2] contracts to dilate, or open, the cervix [3] and push the fetus [4] into the birth canal. The catheter measures the pressure within the amniotic space during contractions and allows physicians to evaluate the strength, ...
متن کاملINTELLIGENT TECHNIQUE OF CANCELING MATERNAL ECG IN FECG EXTRACTION
In this paper, we propose a technique of artificial intelligence called adaptive neuro fuzzy inference system (ANFIS) for canceling maternal electrocardiogram (MECG) in fetal electrocardiogram extraction (FECG).This technique is used to estimate the MECG present in the abdominal signal of a pregnant woman. The FECG is then extracted by subtracting the estimated MECG from the abdominal signal. P...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- EURASIP J. Adv. Sig. Proc.
دوره 2003 شماره
صفحات -
تاریخ انتشار 2003