چکیده

BACKGROUND Basic life support (BLS) guidelines focus on chest compressions with a minimal no-flow fraction (NFF), early defibrillation, and a short perishock pause. By using an automated external defibrillator (AED) lay persons are guided through the process of attaching electrodes and initiating defibrillation. It is unclear, however, to what extent the voice instructions given by the AED might influence the quality of initial resuscitation. METHODS Using a patient simulator, 8 different commercially available AEDs were evaluated within two different BLS scenarios (ventricular fibrillation vs. asystole). A BLS certified instructor acted according to the current European Resuscitation Council 2010 Guidelines and followed all of the AED voice prompts. In a second set of scenarios, the rescuer anticipated the appropriate actions and started already before the AED stopped speaking. A BLS scenario without AED served as the control. All scenarios were run three times. RESULTS The time until the first chest compression was 25 ± 2 seconds without the AED and ranged from 50 ± 3 to 148 ± 13 seconds with the AED depending on the model used. The NFF was .26 ± .01 without the AED and between .37 ± .01 and .72 ± .01 when an AED was used. The perishock pause ranged from 12 ± 0 to 46 ± 0 seconds. The optimized sequence of actions reduced the NFF, which ranged now from .32 ± .01 to .41 ± .01, and the perishock pause ranging from 1 ± 1 to 19 ± 1 seconds. CONCLUSIONS Voice prompts given by commercially available AED merely meet the requirements of current evidence in basic life support. Furthermore, there is a significant difference between devices with regard to time until the first chest compression, perishock pause, no-flow fraction and other objective measures of the quality of BLS. However, the BLS quality may be improved with optimized handling of the AED. Thus, rescuers should be trained on the respective AED devices, and manufacturers should expend more effort in improving user guidance to shorten the NFF and perishock pause.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Implementation of National Resuscitation Guidelines 2006.

The implementation of guidelines released by the National Resuscitation Council in 2006 involved all the main areas of resuscitation, especially basic life support and defibrillation. The emphasis was on community training, creation of simplified programmes, combining cardiopulmonary resuscitation (CPR) and defibrillation, and using simpler training devices. As a result, public access defibrill...

متن کامل

[News in basic life support and semi-automated external defibrillation].

During resuscitation, basic life support (BLS) and automated external defibrillation refer to maneuvers designed to maintain airway patency and support breathing and circulation without equipment other than a barrier device and the use of an automated external defibrillator (AED). We present some of the most important developments incorporated to the new international recommendations for resusc...

متن کامل

Use of automated external defibrillator in Peruvian out-of-hospital environment: improving emergency response in Latin America.

This case report relates out-of-hospital care to a patient with risk factors treated in the out-of-hospital services after cardiac arrest and ventricular fibrillation. The patient was treated according to the standards of basic life support and advanced cardiovascular life support; by applying an automated external defibrillator (AED) with favorable outcome and successful recovery of the patien...

متن کامل

Circumstances of out of hospital cardiac arrest in patients with ischaemic heart disease.

OBJECTIVES To discover the circumstances of out of hospital cardiac death irrespective of resuscitation attempts. DESIGN Prospective community study over the two years 1994 and 1995. SETTING The health districts of Brighton, South Glamorgan, and York, UK. SUBJECTS 1290 victims of sudden death or cardiac arrest caused by coronary heart disease who were under 76 years of age. INTERVENTION...

متن کامل

The knowledge of public access to defibrillation in selected cities in Poland

INTRODUCTION The Public Access to Defibrillation (PAD) program was designed to raise the awareness of sudden cardiac death (SCA) pre-hospital management among the community. The goal of the following research was to confirm the final impact of the Polish PAD program on various resident groups that differ by age, training and education level. MATERIAL AND METHODS The trial total number of part...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 23  شماره 

صفحات  -

تاریخ انتشار 2015