Validation data for the determination of perchlorate in water using ion chromatography with suppressed conductivity detection

نویسندگان

  • Maike A. Seiler
  • Detlef Jensen
  • Udo Neist
  • Ursula K. Deister
  • Franz Schmitz
چکیده

BACKGROUND Perchlorate salts are relatively stable, soluble in water, and migrate into groundwater sources. Groundwater is an essential source for drinking water suppliers. Perchlorate bears health risks as it is identified to impair normal thyroid function by interfering with iodine uptake by the thyroid gland. The development of a sensitive analytical method for the determination of perchlorate is therefore of the highest interest or public health. Ion chromatography is a sensitive method suitable for perchlorate determinations. This manuscript describes the validation of an ion chromatographic method. Perchlorate is determined by ion chromatography (IC) with conductivity detection after suppression (CD) applying isocratic elution. RESULTS In this study, the suitability of IC-CD was tested for synthetic samples, selected environmental water, drinking water, and swimming pool water in order to evaluate potential matrix effects on the perchlorate signal even after sample preparation. A sample injection volume of 750 μL was applied to the selected 2-mm-IC column. In untreated samples, the perchlorate peak can be interfered by neighbouring signals from matrix ions like chloride, nitrate, carbonate, and sulphate. Depending on the concentration of the matrix ions, the perchlorate peak can show asymmetric shape in particular when the perchlorate concentration is low. Recovery is reduced with increasing matrix ion concentrations. Dedicated matrix elimination was applied to minimize such effects. A reporting limit of 1.5 μg/L perchlorate and an expanded measurement uncertainty of 13.2 % were achieved. CONCLUSION The extended method validation proves the applicability of IC based on the EPA 314.0 method for the determination of trace amounts of perchlorate in water samples of different origin. The results support the development of a respective international standard pursued by ISO. The approach evidenced its working robustness and ease of use in terms of eluent preparation, chromatographic resolution, column life time and sample preparation. Due to the simplified analytical workflow of the analytical procedure the application's integration into the collection of methods of interested laboratories should be facilitated.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantitative analysis of perchlorate in extracts of whole fish homogenates by ion chromatography: comparison of suppressed conductivity detection and electrospray ionization mass spectrometry.

The perchlorate anion (ClO4-) is an anthropogenic contaminant of increasing concern in water supplies, and has been shown to disrupt thyroid activity. Most perchlorate analyses are currently carried out by ion chromatography (IC) with suppressed conductivity detection (SCD). While this procedure has been demonstrated to provide acceptable performance for analysis of water samples, the determina...

متن کامل

The Analysis of Perchlorate by Ion Chromatography/Mass Spectrometry Application

A method for the determination of perchlorate anion at sub ppb levels using ion chromatography/mass spectrometry (IC/MS) is described. The IC/MS method follows EPA Method 314 methodology originally developed for IC with conductivity detection at the single ppb range [1]. The IC/MS method is not affected by the addition of the interference matrix described in Method 314 on perchlorate recoveries...

متن کامل

Quantitative Determination of Tartaric Acid in Tolterodine Tartrate by Ion Chromatography Using Conductivity Detection

The present paper deals with the development and validation of analytical method based on a single column high performance Ion chromatography with cation suppressed conductivity detection, developed for quantitation of tartaric acid. The diluent used for the preparation of sample solution was water and injected into a standard chromatographic system connected with 250mm length, 4.0 mm ID and 5....

متن کامل

Determination of trace perchlorate in water: a simplified method for the identification of potential interferences

Background: Perchlorate contamination of water and food poses potential health risks to humans due to the possible interference of perchlorate with the iodide uptake into the thyroid gland. Perchlorate has been found in food and drinking, surface, or swimming pool waters in many countries, including the United States, Canada, France, Germany, and Switzerland, with ion chromatography (IC) being ...

متن کامل

Determination of perchlorate at parts-per-billion levels in plants by ion chromatography.

A method for the analysis of perchlorate in plants was developed, based on dry weight, and applied to the analysis of plant organs, foodstuffs, and plant products. The method reduced greatly the ionic interferences in water extracts of plant materials. The high background conductivity, due to the plant matrix, was reduced sufficiently to allow quantitation of perchlorate with little or no matri...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 28  شماره 

صفحات  -

تاریخ انتشار 2016