Multi-Rod Constructs Can Prevent Rod Breakage and Pseudarthrosis at the Lumbosacral Junction in Adult Spinal Deformity

نویسندگان

  • Robert K. Merrill
  • Jun S. Kim
  • Dante M. Leven
  • Joung Heon Kim
  • Samuel K. Cho
چکیده

STUDY DESIGN Retrospective cohort study. OBJECTIVE To determine if patients fused with multi-rod constructs to the pelvis have a lower incidence of lumbosacral rod failure and pseudarthrosis than those fused with dual-rod constructs. METHODS We performed a retrospective review of consecutive adult spinal deformity patients who underwent long fusion to the pelvis. Inclusion criteria were >5 levels, primary fusion or revision for L5-S1 pseudarthrosis, and minimum 1-year follow-up. Revision patients with indications other than L5-S1 pseudarthrosis were excluded. One-year follow-up plain radiographs were reviewed for rod integrity, and computed tomography scan (CT) was obtained whenever rod breakage was observed. Dual-rod and multi-rod (3 or 4 rods) cohorts were statistically compared. RESULTS There were 31 patients with 15 in the dual-rod group and 16 in the multi-rod group, with average ages of 68 ± 9 and 63 ± 12 years, respectively. No patients in the multi-rod group experienced rod fracture, whereas 6 in the dual-rod group fractured a rod (P = .007), with 4 occurring at the lumbosacral junction (P = .04). CT scan in the 4 lumbosacral rod fracture cases, and surgical exploration in 3, confirmed pseudarthrosis and hypertrophic nonunion at the L5-S1 junction. CONCLUSION Patients with dual-rod constructs had a statistically greater incidence of lumbosacral pseudarthrosis with implant failure than those with multi-rod constructs. CT and surgical exploration showed hypertrophic nonunion as opposed to oligo- or atrophic nonunion. This suggests that mechanical instability, not biology, is the main reason for failure, and could be addressed with the use of multi-rods.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analysis of instrumentation failures after three column osteotomies of the spine

BACKGROUND Correction of fixed spinal imbalance in a sagittal and/or coronal plane frequently needs a tricolumnar wedge resection when the deformity is rigid. Complications associated with deformity correction surgery are pseudoarthrosis and implant failure located along the construct. The purposes of this study were to assess comparative rates of pseudoarthrosis (implant failure) at weaker poi...

متن کامل

Posterior spinal fusion to sacrum in non-ambulatory hypotonic neuromuscular patients: sacral rod/bone graft onlay method

PURPOSE A retrospective study involving 65 non-ambulatory patients with hypotonic neuromuscular scoliosis has assessed the effectiveness of a sacral rod/bone onlay technique for extending spinal fusion to the sacrum. METHODS To extend posterior spinal fusion to the sacrum, we used either 1 Harrington rod and 1 Luque L rod with sublaminar wires in 14 patients (Group 1) or two rods with sublami...

متن کامل

Risk factors for rod fracture after posterior correction of adult spinal deformity with osteotomy: a retrospective case-series

BACKGROUND Osteotomies including pedicle subtraction (PSO) and/or Smith-Peterson (SPO) are used to facilitate surgical correction of adult spinal deformity (ASD), but are associated with complications including instrumentation failure and rod fracture (RF). The purpose of this study was to determine incidence and risk factors for RF, including a clinically significant subset (CSRF), after osteo...

متن کامل

Spinal Deformity in Neurofibromatosis: Classification and Management

The effects of treatment of scoliosis in neurofibromatosis type 1 are less satisfactory than other scoliotic types due to the particular pathogenesis and clinical characteristics. Surgical treatment usually included 360 degrees fusion with instrumentation, but optimal strategies are different according to the degree of deformity. High incidence of pseudarthrosis, extensive bleeding and curve pr...

متن کامل

Biomechanical effects of polyaxial pedicle screw fixation on the lumbosacral segments with an anterior interbody cage support

BACKGROUND Lumbosacral fusion is a relatively common procedure that is used in the management of an unstable spine. The anterior interbody cage has been involved to enhance the stability of a pedicle screw construct used at the lumbosacral junction. Biomechanical differences between polyaxial and monoaxial pedicle screws linked with various rod contours were investigated to analyze the respecti...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2017