Neonatal resuscitation 3: manometer use in a model of face mask ventilation.

نویسندگان

  • C P F O'Donnell
  • P G Davis
  • R Lau
  • P A Dargaville
  • L W Doyle
  • C J Morley
چکیده

BACKGROUND Adequate ventilation is the key to successful neonatal resuscitation. Positive pressure ventilation (PPV) is initiated with manual ventilation devices via face masks. These devices may be used with a manometer to measure airway pressures delivered. The expiratory tidal volume measured at the mask (V(TE(mask))) is a good estimate of the tidal volume delivered during simulated neonatal resuscitation. AIM To assess the effect of viewing a manometer on the peak inspiratory pressures used, the volume delivered, and leakage from the face mask during PPV with two manual ventilation devices in a model of neonatal resuscitation. METHODS Participants gave PPV to a modified resuscitation mannequin using a Laerdal infant resuscitator and a Neopuff infant resuscitator at specified pressures ensuring adequate chest wall excursion. Each participant gave PPV to the mannequin with each device twice, viewing the manometer on one occasion and unable to see the manometer on the other. Data from participants were averaged for each device used with the manometer and without the manometer separately. RESULTS A total of 7767 inflations delivered by the 18 participants were recorded and analysed. Peak inspiratory pressures delivered were lower with the Laerdal device. There were no differences in leakage from the face mask or volumes delivered. Whether or not the manometer was visible made no difference to any measured variable. CONCLUSIONS Viewing a manometer during PPV in this model of neonatal resuscitation does not affect the airway pressure or tidal volumes delivered or the degree of leakage from the face mask.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Neonatal resuscitation 1: a model to measure inspired and expired tidal volumes and assess leakage at the face mask.

BACKGROUND Neonatal resuscitation is a common and important intervention, and adequate ventilation is the key to success. In the delivery room, positive pressure ventilation is given with manual ventilation devices using face masks. Mannequins are widely used to teach and practise this technique. During both simulated and real neonatal resuscitation, chest excursion is used to assess tidal volu...

متن کامل

Neonatal resuscitation 2: an evaluation of manual ventilation devices and face masks.

BACKGROUND The key to successful neonatal resuscitation is effective ventilation. Little evidence exists to guide clinicians in their choice of manual ventilation device or face mask. The expiratory tidal volume measured at the mask (V(TE(mask))) is a good estimate of the tidal volume delivered during simulated neonatal resuscitation. AIM To compare the efficacy of (a) the Laerdal infant resu...

متن کامل

Leak and obstruction with mask ventilation during simulated neonatal resuscitation.

OBJECTIVES To evaluate mask technique during simulated neonatal resuscitation and test the effectiveness of training in optimal mask handling. STUDY DESIGN Seventy participants(consultants, registrars and nurses) from neonatal units were asked to administer positive pressure ventilation at a flow of 8 l/min and a frequency of 40-60/min to a modified leak free, term newborn manikin (lung compl...

متن کامل

Randomized, controlled trial comparing laryngeal mask versus endotracheal intubation during neonatal resuscitation---a secondary publication

BACKGROUND This study aimed to study the feasibility, efficacy and safety of using laryngeal mask (LM) ventilation compared with endotracheal intubation (ETI) during neonatal resuscitation. METHODS Neonates with a heart rate below 60 beats per minute despite 30 s of face mask ventilation were assigned quasi-randomly (odd/even birth date) to LM (n = 36) or ETI (n = 32) ventilation. Differences...

متن کامل

Pilot manikin study showed that a supraglottic airway device improved simulated neonatal ventilation in a low‐resource setting

AIM We compared the performance of personnel in a low-resource setting when they used the I-gel cuffless neonatal laryngeal mask or a face mask on a neonatal airway management manikin. METHODS At Mulago Hospital, Uganda, 25 doctors, nurses and midwives involved in neonatal resuscitation were given brief training with the I-gel and face mask. Then, every participant was observed positioning bo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Archives of disease in childhood. Fetal and neonatal edition

دوره 90 5  شماره 

صفحات  -

تاریخ انتشار 2005