Coated versus noncoated circuits in pediatric cardiopulmonary bypass.
نویسندگان
چکیده
منابع مشابه
In vivo comparison study of FDA-approved surface-modifying additives and poly-2-methoxyethylacrylate circuit surfaces coatings during cardiopulmonary bypass.
The purpose of this double-blind prospective and randomized study was to examine the effects of surface-modifying additives (SMAs) and poly-2-methoxyethylacrylate (PMEA) circuits on platelet count, platelet function (Sonoclot), postoperative chest tube drainage volume, peri- and postoperative blood product use, extubation time, and intensive care time. Terumo noncoated, Terumo-coated (PMEA), Co...
متن کاملHeparin Coated Cardiopulmonary Bypass Circuits in Coronary Artery Surgery- A Clinical Study
Abstract------------------Cardiopulmonary bypass with systemic heparinization causes trauma to blood cells and coagulation defects. Artificial surfaces could be coated by end-linkage binding of heparin (Carmeda Bioactive Surface CBASTM). The use of such surfaces during cardiopulmonary bypass in animals resulted in less postoperative blood loss and better preservation of blood cells. Heparin-coa...
متن کاملOxidant Status following Cardiac Surgery with Phosphorylcholine-Coated Extracorporeal Circulation Systems
Introduction. Extracorporeal circulation (ECC) related systemic oxidative stress is a well-known entity but the underlying mechanisms are not clearly described. Our aim was to investigate the relation between the oxidative stress indices, inflammatory markers, and phosphorylcholine-coated (PCC) ECC systems. Patients and Methods. Thirty-two consecutive coronary artery bypass grafting (CABG) case...
متن کاملQuantitative evaluation of heparin-coated versus non-heparin-coated bypass circuits during cardiopulmonary bypass.
The extracorporealization of blood activates various elements of the fibrinolytic, coagulation, and complement systems. It is theorized that advancements in biocompatibility ameliorate many of the changes leading to improved patient management. The purpose of this study was to determine if heparin-coated circuit (HCC) utilization during cardiopulmonary bypass enhances patient outcomes in a cost...
متن کاملEvaluation of biocompatible cardiopulmonary bypass circuit use during pediatric open heart surgery.
The contact of blood with nonbiological surfaces during cardiopulmonary bypass (CPB) induces a whole body inflammatory response and increases postoperative morbidity directly related to bleeding complications and end organ dysfunction. Methods to reduce these effects have included modification of extracorporeal circuits through biocompatible coating of disposables and the application of various...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- ASAIO journal
دوره 51 5 شماره
صفحات -
تاریخ انتشار 2005