Performance characteristics of an HPLC assay for urinary albumin.
نویسندگان
چکیده
Microalbuminuria is a marker of diabetic nephropathy and cardiovascular risk. Immunoassays underestimate the amount of intact albumin present in urine. The purpose of this study was to evaluate a new urinary albumin assay that uses size exclusion high-performance liquid chromatography (HPLC). We determined the limit of detection, linearity, imprecision, a comparison with an immunoturbidimetric assay, and pediatric and adult reference intervals. The limit of detection was 3.4 mg/L. The assay was linear from 4 to 240 mg/L. Total imprecision was less than 10% from 16 to 206 mg/L. Comparison of the albumin/creatinine ratio by HPLC with an immunoturbidimetric method showed positive proportional bias, which decreased with increasing concentrations of albumin. Nonparametric reference intervals were 22 to 250 mg/g for girls, 20 to 130 mg/g for boys, 14 to 62 mg/g for women, and 10 to 37 mg/g for men. This HPLC assay for urinary albumin shows acceptable performance and quantifies albumin species that are not detected by immunoassay. Separate reference intervals for children and adults seem necessary.
منابع مشابه
Comparison between immunoturbidimetry, size-exclusion chromatography, and LC-MS to quantify urinary albumin.
BACKGROUND The accurate and precise measurement of urinary albumin is critical, since even minor increases are diagnostically sensitive indicators of renal disease, cardiovascular events, and risk for death. To gain insights into potential measurement biases, we systematically compared urine albumin measurements performed by LC-MS, a clinically available immunoturbidimetric assay, and size-excl...
متن کاملCoelution of other proteins with albumin during size-exclusion HPLC: Implications for analysis of urinary albumin.
BACKGROUND Size-exclusion HPLC has been used as an alternative to immunoassays for quantifying urinary albumin (microalbumin). Systematically higher values for the HPLC method have been proposed to result from nonimmunoreactive albumin. METHODS We evaluated separation of purified proteins and urinary components by size-exclusion HPLC using a Zorbax Bio Series GF-250 column eluted with phospha...
متن کاملComparison of Microbiological and High-Performance Liquid Chromatographic Methods for Determination of Clarithromycin Levels in Plasma
An agar well diffusion bioassay method for determination of clarithromycin in human plasma, using Micrococcus Luteus ATCC 9341 as the assay organism, was compared with a selective high-performance liquid chromatographic (HPLC) method with UV detection. Spiked plasma was used to prepare standard and control samples for both methods. The results of the bioassay analyses with spiked plasma samples...
متن کاملComparison of Microbiological and High-Performance Liquid Chromatographic Methods for Determination of Clarithromycin Levels in Plasma
An agar well diffusion bioassay method for determination of clarithromycin in human plasma, using Micrococcus Luteus ATCC 9341 as the assay organism, was compared with a selective high-performance liquid chromatographic (HPLC) method with UV detection. Spiked plasma was used to prepare standard and control samples for both methods. The results of the bioassay analyses with spiked plasma samples...
متن کاملApparent loss of urinary albumin during long-term frozen storage: HPLC vs immunonephelometry.
BACKGROUND Urinary albumin detection by immunonephelometry is decreased by approximately 30% in samples that have been frozen at -20 degrees C. An HPLC method for assessment of urinary albumin that detects immunoreactive and immunochemically nonreactive albumin has been introduced as an alternative to immunonephelometry. We investigated whether this technique is affected by sample temperature, ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- American journal of clinical pathology
دوره 124 2 شماره
صفحات -
تاریخ انتشار 2005