Late type IIIb endoleak after endovascular aneurysm repair: case report and review of the literature.

نویسندگان

  • F Bucci
  • L Fiengo
  • N Valerio
  • M Ferdani
چکیده

PURPOSE To report a case of type IIIb endoleak developed six years after endovascular abdominal aortic aneurysm repair (EVAR). CASE REPORT A 75-year-old man underwent successful Talent™ stent-graft positioning to treat a 53 mm abdominal aortic aneurysm. Subsequently the patient did well and yearly routine control computerized tomography (CT) was unremarkable. Six years later the patient suddenly developed abdominal pain irradiating to the back. An emergency angio-CT showed the presence of a type IIIb endoleak arising from the main body of the endograft. There weren't signs of fissuration or rupture. Aneurysm diameter was 85 mm as compared to 52 mm on a CT performed ten months earlier. The patient underwent successful positioning of an aorto-monoiliac endograft followed by the occlusion of the controlateral limb and a femoro-femoral crossover dacron bypass graft. Three months later the patient presented again because of the sudden onset of abdominal pain. On angio-CT aneurysm size was increased up to 11 cm. A distal type I endoleak was found and treated by placing an iliac extension to the right external iliac artery. After uneventful postoperative course the patient was discharged in good general conditions. Control angio-CT done after six months showed the complete exclusion of the large aneurysm sac. CONCLUSIONS Type IIIb endoleaks can be safely treated by endovascular positioning of an aorto-monoiliac stent-graft followed by the occlusion of the controlateral limb and a femoro-femoral crossover dacron bypass graft. Continuous surveillance after EVAR is mandatory.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Delayed Type IIIb endoleak secondary to graft fabric tear 7 years following implantation of a Medtronic Talent endovascular aortic device: A case report and review of the literature

OBJECTIVES To report a rare case of delayed Type IIIb endoleak secondary to fabric tear following implantation of a Medtronic Talent endovascular device. METHODS A 83-year old gentleman underwent elective endovascular aneurysm repair for infrarenal abdominal aortic aneurysm with a Medtronic bifurcated stent graft in 2008. RESULTS Seven years after the initial repair, imaging surveillance re...

متن کامل

Late type III endoleak after thoracic endovascular aneurysm repair and previous infrarenal stent graft implantation – a case report and review of the literature

Thoracic endovascular aortic repair (TEVAR) effectively improved the results of thoracic aortic aneurysm treatment. TEVAR is a less invasive procedure that can be performed under local anesthesia with shorter hospital stay. The perioperative morbidity and mortality rates are lower for endovascular than open repair, but the rate of secondary interventions is higher for TEVAR. We report a case of...

متن کامل

Late Sac Rupture due to a Type IV Endoleak after Previous Endovascular Aortic Aneurysm Repair: A Case Report

Type IV endoleaks have been identified as endoleaks of low flow, and rupture risk has been estimated to be minimal in literature. Therefore, conservative treatment has been recommended in most cases. We are presenting a rare case of late rupture due to type IV endoleak that was treated with open repair applying a novel surgical technique.

متن کامل

An Aortoenteric Fistula Arising after Endovascular Management of a Mycotic Abdominal Aortic Aneurysm Complicated with a Psoas Abscess

Mycotic aortic aneurysms account for 1–3% of all aortic aneurysms. The management of this disease is controversial. Since open surgical repair is associated with high morbidity and mortality rates, endovascular aneurysm repair is an alternative treatment method with promising early and midterm outcomes, although its long-term durability is unknown.Secondary aortoenteric fistulas may occur iatro...

متن کامل

Endovascular Repair of Ruptured Popliteal Artery Aneurysms: A Case Report and Review of the Literature

OBJECTIVE/BACKGROUND The objectives were to report the management and outcomes of a 96-year-old man who presented with an acutely swollen right leg due to a ruptured popliteal aneurysm, and to review the relevant literature. METHODS A ruptured popliteal artery aneurysm is a rare diagnosis and is one that is often missed at time of presentation. Previous case reports have documented successful...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Il Giornale di chirurgia

دوره 32 6-7  شماره 

صفحات  -

تاریخ انتشار 2011