M-channel gating and simulation.
نویسندگان
چکیده
Single potassium M-channels in rat sympathetic neurons have multiple voltage-dependent kinetic components in their activity: short, medium, and long closed times (tau(CS), tau(CM), and tau(CL)) and short and long open times (tau(OS) and tau(OL)). All five components can be detected in cell-attached patches, but only four of them (tau(CS), tau(CM), tau(OS), and tau(OL)) in excised patches (, J. Physiol. (Lond.). 472:711-724; 1996, Neuron. 16:151-162; 1996, Neuropharmacology. 35:933-947). Analysis of the burst structure of activity recorded from cell-attached and excised inside-out patches showed it to be consistent with the sequential kinetic scheme C(L) left arrow over right arrow O(S) left arrow over right arrow C(M) left arrow over right arrow O(L) left arrow over right arrow C(S). Using this scheme and experimentally determined kinetic parameters, we successfully simulated the activity of M-channels both under steady-state conditions and during depolarizing voltage steps. Consistent with the characteristic behavior of macroscopic M-current, ensemble currents constructed from simulated M-channels had exponential activation and deactivation, with no delays, when tested in the range between -50 and -20 mV.
منابع مشابه
Gating Behavior of Endoplasmic Reticulum Potassium Channels of Rat Hepatocytes in Diabetes
Background: Defects in endoplasmic reticulum homeostasis are common occurrences in different diseases, such as diabetes, in which the function of endoplasmic reticulum is disrupted. It is now well established that ion channels of endoplasmic reticulum membrane have a critical role in endoplasmic reticulum luminal homeostasis. Our previous studies showed the presence of an ATP-sensitive cationic...
متن کاملA simulation study of calcium release channel
The IP3R calcium release channel has been simulated using a stochastic simulation algorithm (SSA;Gillespie algorithm) and De young-Keiser model. A set of different concentration for Cat' and IP3 havebeen used. Considering the Number of molecules in each state, a non linear behavior of the system can beseen clearly. The inhibiting role of the Ca+2 on the open state (X110) has been studied. The d...
متن کاملاثرات میدان الکترومغناطیسی تلفن همراه بر عملکرد تک نانوکانال پروتیینی OmpF: یک رویکرد تجربی
Background: Widespread of telecommunication systems in recent years, have raised the concerns on the possible danger of cell phone radiations on human body. Thus, the study of the electromagnetic fields on proteins, particularly the membrane nano channel forming proteins is of great importance. These proteins are responsible for keeping certain physic-chemical condition within cells and managin...
متن کاملTargeted Molecular Dynamics Study of C-Loop Closure and Channel Gating in Nicotinic Receptors
The initial coupling between ligand binding and channel gating in the human alpha7 nicotinic acetylcholine receptor (nAChR) has been investigated with targeted molecular dynamics (TMD) simulation. During the simulation, eight residues at the tip of the C-loop in two alternating subunits were forced to move toward a ligand-bound conformation as captured in the crystallographic structure of acety...
متن کاملNon-Equilibruim Molecular Dynamics Simulation of Poiseuille Flow in a Nanochannel
The numerical simulation of a Poiseuille flow in a narrow channel using the molecular dynamics simulation (MDS) is performed. Poiseuille flow of liquid Argon in a nanochannel is simulated by embedding the fluid particles in a uniform force field. Density, velocity and Temperature profiles across the channel are investigated. When particles will be inserted into the flow, it is expected that the...
متن کاملEnergy and Exergy Evaluation of Multi-channel Photovoltaic/Thermal Hybrid System: Simulation and Experiment
In this research, a pilot study and analysis of an innovative multi-channel photovoltaic/thermal (MCPV/T) system in a geographic location (35° 44' 35'' N, 50° 57' 25'' E) has been carried out. This system consists of integrating a photovoltaic panel and two PV/T heat-sink converters. The total electrical, exergy and energy efficiencies of the system at air flow rate of 0.005 kg/s and radiation ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Biophysical journal
دوره 77 2 شماره
صفحات -
تاریخ انتشار 1999