BACKGROUND The low shock energy used during internal atrial defibrillation may decrease the need for sedation during defibrillation with an implantable atrial defibrillator. METHODS AND RESULTS The atrial defibrillator (Metrix Atrioverter) was implanted in 12 patients. During the in-hospital treatment of atrial fibrillation (AF) episodes, intravenous sedation was given only on patient request. The Atrioverter was programmed for ambulatory therapy in 4 patients. Efficacy, number of shocks delivered, and sedation requirements were recorded. A total of 393 shocks (1.8+/-1. 6 shocks/AF episode) were delivered to treat 213 AF episodes; 85 of 213 AF episodes (40%) were treated away from the hospital. Sinus rhythm was restored in 195 AF episodes (92%). Five patients never requested sedation. No sedation was needed for ambulatory-treated AF episodes. During the treatment of 26 of 213 AF episodes (12%), 75 shocks were delivered after patients received sedation. The number of shocks required to treat an AF episode determined the need for sedation (4.3+/-2.1 shocks for AF episodes requiring sedation versus 2+/-1 shocks for AF episodes requiring no sedation; P<0.001). These additional shocks were needed to treat immediate reinitiation of AF (14 episodes) or initial failure to cardiovert (4 episodes). For 8 AF episodes, sedation was requested before the first shock. CONCLUSIONS This study suggests that, in a selected group of patients, AF can be treated with Atrioverter therapy without sedation. Successful ambulatory treatment of AF episodes with the Atrioverter, programmed to deliver </=2 shocks, did not require sedation. When multiple shocks were required to treat an AF episode, the need for sedation increased and included patients initially not requesting sedation.
منابع مشابه
Programmed inappropriate ICD ventricular defibrillation for cardioversion of persistent atrial fibrillation
In this report we briefly describe a patient with a dual chamber implantable cardioverter defibrillator in the context of severe ischemic cardiomyopathy who developed persistent atrial fibrillation. After appropriate anticoagulation and under mild sedation the patient was successfully cardioverted to sinus rhythm after a programmed ventricular synchronized defibrillation using his defibrillator...
متن کاملSuccess of Device-Based Methods for Atrial Tachyarrhythmia Induction during Implantation of an Implantable Cardioverter Defibrillator with Atrial Therapy
In addition to standard ventricular therapy, cardioversion using an implantable cardioverter defibrillator (ICD) with atrial therapy is one of the many new options available for treating atrial tachyarrhythmias. New data suggest that shock efficacy for AF depends on identifying atrial defibrillation thresholds (DFT) and programming the first atrial shock to at least two times the atrial DFT [1]...
متن کاملNovel passive implantable atrial defibrillator using transcutaneous radiofrequency energy transmission successfully cardioverts atrial fibrillation.
BACKGROUND Conventional methods for cardioversion of atrial fibrillation (AF) to sinus rhythm have numerous difficulties. A novel method for cardioversion using the passive implantable atrial defibrillator (PIAD) was tested in acute animal models. This device does not have a battery or a capacitor to store energy and is activated by transferring RF energy across the skin from an external transm...
متن کاملMarked reduction in atrial defibrillation thresholds with repeated internal cardioversion.
OBJECTIVES This study was performed to assess the atrial defibrillation threshold in patients with recurrent atrial fibrillation (AF) using repeated internal cardioversion. BACKGROUND Previous studies in patients with chronic AF undergoing internal cardioversion have shown this method to be effective and safe. However, current energy requirements might preclude patients with longer-lasting AF...
متن کاملEffect of the implantable atrial defibrillator on the natural history of atrial fibrillation.
INTRODUCTION The purpose of our study was to evaluate the effect of repeated cardioversion with an implantable atrial defibrillator on the clinical outcome of patients with atrial fibrillation. METHODS AND RESULTS The effects of the implantable atrial defibrillator on the total duration of atrial fibrillation, number of atrial fibrillation recurrences, and left atrial size were evaluated pros...