Measurement of carboxyhemoglobin and methemoglobin by pulse oximetry: a human volunteer study.

نویسندگان

  • Steven J Barker
  • Jeremy Curry
  • Daniel Redford
  • Scott Morgan
چکیده

BACKGROUND A new eight-wavelength pulse oximeter is designed to measure methemoglobin and carboxyhemoglobin, in addition to the usual measurements of hemoglobin oxygen saturation and pulse rate. This study examines this device's ability to measure dyshemoglobins in human volunteers in whom controlled levels of methemoglobin and carboxyhemoglobin are induced. METHODS Ten volunteers breathed 500 ppm carbon monoxide until their carboxyhemoglobin levels reached 15%, and 10 different volunteers received intravenous sodium nitrite, 300 mg, to induce methemoglobin. All were instrumented with arterial cannulas and six Masimo Rad-57 (Masimo Inc., Irvine, CA) pulse oximeter sensors. Arterial blood was analyzed by three laboratory CO-oximeters, and the resulting carboxyhemoglobin and methemoglobin measurements were compared with the corresponding pulse oximeter readings. RESULTS The Rad-57 measured carboxyhemoglobin with an uncertainty of +/-2% within the range of 0-15%, and it measured methemoglobin with an uncertainty of 0.5% within the range of 0-12%. CONCLUSION The Masimo Rad-57 is the first commercially available pulse oximeter that can measure methemoglobin and carboxyhemoglobin, and it therefore represents an expansion of our oxygenation monitoring capability.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Recent advances in pulse oximetry

Conventional pulse oximetry uses two wavelengths of light (red and infrared) transmitted through a finger and a photodetector to analyze arterial hemoglobin oxygen saturation and pulse rate. Recent advances in pulse oximetry include: extended analysis of the photo plethysmographic waveform; use of multiple wavelengths of light to quantify methemoglobin, carboxyhemoglobin and total hemoglobin co...

متن کامل

The measurement of dyshemoglobins and total hemoglobin by pulse oximetry.

PURPOSE OF REVIEW Recent advances in pulse oximetry have made it possible to noninvasively measure total hemoglobin, as well as the two most common dyshemoglobins. This review will trace the development and clinical application of multiwavelength pulse oximetry. RECENT FINDINGS Until now, commercially produced pulse oximeters have utilized two wavelengths of light and could measure only the r...

متن کامل

Methemoglobinemia and Pulse Oximetry

In reviewing the article “Methemoglobinemia: Sudden Dyspnea and Oxygen Desaturation After Esophagoduodenoscopy,” in the August 2004 issue of RESPIRATORY CARE,1 I found the article suggested that, during the esophagoduodenoscopy procedure the patient’s blood oxygen saturation (measured via pulse oximetry) began to drop rapidly, and a saturation of 54% registered on the pulse oximeter while the p...

متن کامل

Non-invasive measurements of carboxyhemoglobin and methemoglobin in children with sickle cell disease.

Assessment of oxyhemoglobin saturation in patients with sickle cell disease (SCD) is vital for prompt recognition of hypoxemia. The accuracy of pulse oximeter measurements of blood oxygenation in SCD patients is variable, partially due to carboxyhemoglobin (COHb) and methemoglobin (MetHb), which decrease the oxygen content of blood. This study evaluated the accuracy and reliability of a non-inv...

متن کامل

Absorption spectra of human fetal and adult oxyhemoglobin, de-oxyhemoglobin, carboxyhemoglobin, and methemoglobin.

We determined the millimolar absorptivities of the four clinically relevant derivatives of fetal and adult human hemoglobin in the visible and near-infrared spectral range (450-1000 nm). As expected, spectral absorption curves of similar shape were found, but the small differences between fetal and adult hemoglobin absorptivity were important enough that they should be taken into account in mul...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Anesthesiology

دوره 105 5  شماره 

صفحات  -

تاریخ انتشار 2006