Baroreflexes of the rat. III. Open-loop gain and electroencephalographic arousal.
نویسندگان
چکیده
In early studies of humans, baroreflex sensitivity was found to be higher during sleep; however, subsequent observations in several species, including humans, have been at variance with the original reports. Sleep and arousal are behavioral states, and it is difficult to accurately and repeatedly measure baroreflex sensitivity in behaving animals. However, pharmacologically immobilized (neuromuscularly blocked) rats have apparently normal sleep-wakefulness cycles, and baroreflex gain can be measured directly in this preparation. Using the delta band of the EEG (EEG(delta)) as an index of sleep and arousal and open-loop aortic depressor nerve (ADN) stimulation as a baroreflex input, we found that blood pressure (BP) level depended on arousal (r = -0.416; P < 0.0001), and BP baroreflex gain depended on BP level (r = 0.496; P < 0.0001), but that BP baroreflex gain was independent of arousal (r = 0.001; NS). Heart period (HP) was different; although HP level depended on arousal (r = 0.352; P < 0.0001), HP baroreflex gain did not depend on HP level (r = 0.029; NS), and HP baroreflex gain increased with arousal (r = 0.315; P < 0.0001). A partial-correlations analysis showed that the presence of the relationship between BP level and BP baroreflex gain probably attenuated the relationship between arousal and BP gain. The results are consistent 1) with physiological findings showing that arousal attenuates afferent transmission through the nucleus of the solitary tract and enhances sympathoinhibition at the rostral ventrolateral medulla; and 2) with observations in humans and animals showing increased cardiac baroreflex sensitivity during sleep, but little if any effect of sleep on BP baroreflex sensitivity. The findings are relevant to all methods of baroreflex gain estimation that use HP as the index of baroreflex activation.
منابع مشابه
Carotid and aortic baroreflexes of the rat: II. Open-loop frequency response and the blood pressure spectrum.
To determine the relationship between blood pressure (BP) variability and the open-loop frequency domain transfer function (TF) of the baroreflexes, we measured the pre- and postsinoaortic denervation (SAD) spectra and the effects of periodic and step inputs to the aortic depressor nerve and isolated carotid sinus of central nervous system-intact, neuromuscular-blocked (NMB) rats. Similar to pr...
متن کاملStudying Dynamic behavior of Distributed Parameter Processes Behavior Based on Dominant Gain Concept and it’s Use in Controlling these Processes
In this paper, distributed parameter process systems behavior is studied in frequency domain. Based on the dominant gain concept that is developed for such studies, a method is presented to control distributed parameter process systems. By using dominant gain concept, the location of open loop zeros, resulted from the time delay parameter in the process model, were changed from the right half p...
متن کاملA Closed Loop Control of Quadratic Boost Converter Using PID Controller
This paper presents an implementation of open loop and closed loop control of Quadratic boost converter using PID controller. Quadratic boost converter consists of boost converter and fly back converter driven by a single switch. Quadratic boost converter QBC is designed especially for regulating the DC interface between various micro sources and dc-ac inverter to electricity grid. Quadratic b...
متن کاملThe Effect of physical Activity on Spontaneous Electroencephalographic Activity in Rat
Introduction:Exercise and physical activity are important factors for human health.It has been reported that exercise can be considerably useful in the teratment of psychological diseases.in the present study the effect of running on Spontaneous Electroencephalographic Activity (EEG) of rats was investigated. Method:Male wistar rats weighting 190-250 gr were selected and divided into contro...
متن کاملControl of Flexible Link Robot using a Closed Loop Input-Shaping Approach
This paper is has addressed the Single Flexible Link Robot. The dynamical model is derived using Euler-Lagrange equation and then a proper controller is designed to suppress a vibration based-on Input-Shaping (IS) method. But, IS control method is an open loop strategy. Due to the weakness of open loop control systems, a closed loop IS control system is proposed. The achieved closed loop c...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- American journal of physiology. Regulatory, integrative and comparative physiology
دوره 286 3 شماره
صفحات -
تاریخ انتشار 2004