Optical profiling using white light interference in spectral domain
نویسندگان
چکیده
The rapidly developing fields of Micro-Electro Mechanical System (MEMS) and micro optics require non contact and high precision measurements. Optical profilers are ideally suited for this. Monochromatic Phase Shifting Interferometry(PSI) can be used to measure slowly varying profiles and step height of less than half a wavelength. White light interferometry is used when large step height are to be measured. White Light interferogram may be considered as an incoherent superposition of a large number of monochromatic interferograms. These individual interferogram may be accessed at the output of a spectroscope when the white light interferogram is imaged at its entrance slit. For a given optical path difference(OPD) in the interferometer, the phases of these interferograms are different and are linearly related to the wave number of the constituent spectral component. If the phases of all the constituent interferograms are determined, the OPD can be obtained as the slope of the phase versus wave number line. We recently proposed that conventional PZT phase shifting can be used for this purpose. The OPD is related to the height of the test object at a point. If OPD is measured along the entire entrance slit of the spectroscope, a line profile of the object can be determined. In this paper we show that the profile obtained from the slope can be improved by using the monochromatic phase data which is already available from the measurement. Further this paper will also focus on problems as the measurement range is increased.
منابع مشابه
Performance of the Wavelet Transform-Neural Network Based Receiver for DPIM in Diffuse Indoor Optical Wireless Links in Presence of Artificial Light Interference
Artificial neural network (ANN) has application in communication engineering in diverse areas such as channel equalization, channel modeling, error control code because of its capability of nonlinear processing, adaptability, and parallel processing. On the other hand, wavelet transform (WT) with both the time and the frequency resolution provides the exact representation of signal in both doma...
متن کاملWhite Light Spectral Interferometry for Real-time Surface Profile Measurement
This paper presents a high speed surface profile optical measurement technique based on white light spectral interferometry and parallel signal processing using a general purpose graphic processing unit (GPGPU). A white light source is used to acquire the surface profile of the sample instantly in real time through a cylindrical Michelson interferometer. The interference signals are resolved by...
متن کاملRetinal Ganglion Cell Complex in Alzheimer Disease: Comparing Ganglion Cell Complex and Central Macular Thickness in Alzheimer Disease and Healthy Subjects Using Spectral Domain-Optical Coherence Tomography
Introduction: Alzheimer disease (AD) is the most common form of dementia worldwide. The modalities to diagnose AD are generally expensive and limited. Both the central nervous system (CNS) and the retina are derived from the cranial neural crest; therefore, changes in retinal layers may reflect changes in the CNS tissue. Optical coherence tomography (OCT) machine can show delicate retinal layer...
متن کاملTime-domain surface profile imaging via a hyperspectral Fourier transform spectrometer.
We describe a method for time-domain surface profile measurements via white-light reflection spectroscopy using a hyperspectral Fourier transform spectrometer (HS-FTS). This technique measures the frequency of the spectral modulation of reflected light from a multilayer optical surface and reports the spatially resolved optical thickness. Owing to the Fourier relationship, the Fourier transform...
متن کاملبررسی پایایی و تکرار پذیری دستگاه Spectral domain optical coherence tomography در اندازه گیری ضخامت ماکولا در چشمهای طبیعی قبل و بعد از گشاد کردن مردمک
Background: optical coherence tomography is one of the most valuable imaging techniques in the evaluation of macula. Objective: to investigate the repeatability and reproducibility of OCT in measuring the macular thickness in normal eyes before and after pupil dilation. Methods: A total of 44 eyes were enrolled. All subjects underwent macular thickness measurement using the Cirrus SD-OCT ma...
متن کامل