Identification of high frequency transformer model parameters

نویسنده

  • A. Keyhani
چکیده

A two stage model is used to model the high frequency transient behavior of two winding transformers. The assumed transformer model’s parameters are estimated using the maximum likelihood estimation technique and the Kalman filter based on the time response data. Simulations are carried out using the frequency response data generated based on an assumed transformer model. The transfer function time constants for the obtained frequency response data are estimated using the nonlinear least squares technique. The resulting values are then used to generate the time response data for the same transformer. The parameters of the chosen two stage transformer model are estimated in two steps. First the single stage model is identified and subsequently the remaining parameters of the two stage model are estimated using the maximum likelihood method. The estimation results for a two-stage two winding transformer model are presented.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Power Auto-transformer Mechanical Faults Diagnosis ‎Using Finite Element based FRA

Frequency response analysis (FRA) is a sensitive ‎method established for testing the mechanical integrity of ‎transformers. However, interpretation of FRA signature still ‎needs expert opinions and there is no FRA interpretation code ‎generally accepted. Various mechanical faults with different ‎extents on power transformers are required to aid FRA ‎interpretation. To address this challenge, in...

متن کامل

بکارگیری مدار معادل مشروح توسعه‌یافته در ابعاد بزرگ برای مطالعه حالت گذرای ترانسفورماتور

In this paper, frequency response analysis (FRA) of transformer based on the detailed model of the transformer windings, is investigated. The determination of the detailed model parameters, which can be considered as a large scale model, is  a complex task. To overcome this problem, a heuristic method is presented in this paper. This method is applied to a large scale detailed model with n...

متن کامل

Winding Deformation Identification Using A Particle Swarm Optimiser with Passive Congregation for Power Transformers

This paper presents a new approach to identify distributed parameters of a lumped-element model for a power transformer. A simplified circuit of a lumped-element model is developed to calculate frequency responses of transformer windings in a wide range of frequency domain. In order to seek optimal parameters of the simplified circuit of the transformer, an intelligent learning technique, based...

متن کامل

Modal parameters identification of power transformer winding based on improved Empirical Mode Decomposition method

Modal parameters of power transformer winding are closely related to transformer manufacturing and detection technology of winding deformation based on vibration analysis method. Aimed at identifying the modal parameters of transformer winding accurately, a modal experiment is designed and made on a real 10 kV power transformer. An improved Empirical Mode Decomposition (EMD) algorithm is propos...

متن کامل

Reliability Model of Power Transformer with ONAN Cooling

Reliability of a power system is considerably influenced by its equipments. Power transformers are one of the most critical and expensive equipments of a power system and their proper functions are vital for the substations and utilities. Therefore, reliability model of power transformer is very important in the risk assessment of the engineering systems. This model shows the characteristic...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004