High-resolution intravascular magnetic resonance quantification of atherosclerotic plaque at 3T

نویسندگان

  • Di Qian
  • Paul A Bottomley
چکیده

BACKGROUND The thickness of fibrous caps (FCT) of atherosclerotic lesions is a critical factor affecting plaque vulnerability to rupture. This study tests whether 3 Tesla high-resolution intravascular cardiovascular magnetic resonance (CMR) employing tiny loopless detectors can identify lesions and accurately measure FCT in human arterial specimens, and whether such an approach is feasible in vivo using animal models. METHODS Receive-only 2.2 mm and 0.8 mm diameter intravascular loopless CMR detectors were fabricated for a clinical 3 Tesla MR scanner, and the absolute signal-to-noise ratio determined. The detectors were applied in a two-step protocol comprised of CMR angiography to identify atherosclerotic lesions, followed by high-resolution CMR to characterize FCT, lesion size, and/or vessel wall thickness. The protocol was applied in fresh human iliac and carotid artery specimens in a human-equivalent saline bath. Mean FCT measured by 80 μm intravascular CMR was compared with histology of the same sections. In vivo studies compared aortic wall thickness and plaque size in healthy and hyperlipidemic rabbit models, with post-mortem histology. RESULTS Histology confirmed plaques in human specimens, with calcifications appearing as signal voids. Mean FCT agreed with histological measurements within 13% on average (correlation coefficient, R = 0.98; Bland-Altman analysis, -1.3 ± 68.9 μm). In vivo aortic wall and plaque size measured by 80 μm intravascular CMR agreed with histology. CONCLUSION Intravascular 3T CMR with loopless detectors can both locate atherosclerotic lesions, and accurately measure FCT at high-resolution in a strategy that appears feasible in vivo. The approach shows promise for quantifying vulnerable plaque for evaluating experimental therapies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High-resolution intravascular magnetic resonance imaging: monitoring of plaque formation in heritable hyperlipidemic rabbits.

BACKGROUND The individual makeup of atherosclerotic plaque has been identified as a dominant prognostic factor. With the use of an intravascular magnetic resonance (MR) catheter coil, we evaluated the effectiveness of high-resolution MR in the study of the development of atherosclerotic lesions in heritable hyperlipidemic rabbits. METHODS AND RESULTS Sixteen hyperlipidemic rabbits were invest...

متن کامل

Scan-Rescan Reproducibility of High Resolution Magnetic Resonance Imaging of Atherosclerotic Plaque in the Middle Cerebral Artery

PURPOSE To evaluate the scan-rescan reproducibility of high-resolution magnetic resonance imaging (MRI) of middle cerebral artery (MCA) plaque, and calculate the number of subjects needed for future longitudinal clinical studies. MATERIAL AND METHODS Twenty two patients with MCA plaque were scanned twice by a T2-weighted fast-spin-echo sequence at 3T. Areas and volumes of MCA lumen, total ves...

متن کامل

Review of Journal of Cardiovascular Magnetic Resonance 2012 Dudley

There were 90 articles published in the Journal of Cardiovascular Magnetic Resonance (JCMR) in 2012, which is an 8% increase in the number of articles since 2011. The quality of the submissions continues to increase. The editors are delighted to report that the 2011 JCMR Impact Factor (which is published in June 2012) has risen to 4.44, up from 3.72 for 2010 (as published in June 2011), a 20% i...

متن کامل

New imaging techniques for diagnosing coronary artery disease.

New tomographic cardiovascular imaging tests, such as intravascular ultrasonography (IVUS), coronary computed tomography (CT) angiography and magnetic resonance imaging (MRI), can be used to assess atherosclerotic plaques for the characterization and early staging of coronary artery disease (CAD). Although IVUS images have very high resolution capable of revealing very early preclinical CAD, it...

متن کامل

Intravascular 3.0T MR Imaging: A feasibility Study in Swine

Introduction: Magnetic resonance imaging (MRI) is a useful imaging tool for visualization of vessel walls and characterization of atherosclerotic lesions, providing high resolution and multiple imaging planes with no risk of radiation. The use of MR technology is, however, limited in imaging of deep-seated arteries, primarily due to insufficient signal-to-noise ratio (SNR) with a surface coil. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 2012