A comparison of respiratory care workload with 2 different nebulizers.

نویسندگان

  • Edward R Hoisington
  • Robert L Chatburn
  • James K Stoller
چکیده

UNLABELLED Aerosol therapy via small-volume nebulizer (SVN) accounts for a large proportion of the respiratory care workload. Treatment time is mostly nebulization time, which is highly variable, depending on SVN design. We studied the workload effect of adopting a faster nebulizer. We hypothesized that time saved by faster SVN treatment can be used by respiratory therapists for other patient-care activities. METHODS We compared day-shift workload distribution in a post-thoracic-surgery ward during 2 consecutive 30-day periods. To deliver bronchodilators (3 mL unit dose), during the baseline period we used the VixOne nebulizer (average nebulization time 9 min), and during the intervention period we used the NebuTech HDN (nebulization time limited to 3 min). We recorded the per-shift number of various respiratory-therapy procedures, which have been assigned standard treatment times, and compared the per-shift numbers of procedures during the baseline and intervention periods. RESULTS The per-shift number of procedures were similar during the baseline and intervention periods (33.8/shift vs 33.3/shift, P = .68), as was the per-shift number of SVN treatments (11.9/shift vs 11.8/shift, respectively, P = .81). The per-shift time required for the procedures was greater during the baseline period (4.7 h vs 3.6 h, P < .001). The per-shift time available to deliver optional value-added respiratory therapies was higher in the intervention period (0.75 h vs 0.50 h, P < .04). The time savings from the faster nebulizer corresponded to 1.8 full-time equivalents and theoretical net annual savings of $66,491. We did not use treatment "stacking" (ie, simultaneous administration of SVN treatments to multiple patients). CONCLUSIONS The NebuTech HDN substantially reduces SVN-administration time, without adverse effects or events, and the time savings were used for value-added patient-care activities. Shorter treatment times can play a role in coping with the national shortage of qualified respiratory therapists.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Albuterol delivery by 4 different nebulizers placed in 4 different positions in a pediatric ventilator in vitro model.

BACKGROUND The type of aerosol generator and the position in the ventilator circuit are crucial to determine aerosol delivery during mechanical ventilation. We compared lung deposition of albuterol aerosols generated by 4 different nebulizers placed in-line in 4 different positions in a pediatric ventilator model. METHODS Two brands of continuously operated jet nebulizer (6 L/ min, oxygen), a...

متن کامل

Physicochemical aspects and efficiency of albuterol nebulization: comparison of three aerosol types in an in vitro pediatric model.

BACKGROUND Advances in nebulizer design have produced both ultrasonic nebulizers and devices based on a vibrating mesh (vibrating mesh nebulizers), which are expected to enhance the efficiency of aerosol drug therapy. The aim of this study was to compare 4 different nebulizers, of 3 different types, in an in vitro model using albuterol delivery and physical characteristics as benchmarks. METH...

متن کامل

Radioaerosol Pulmonary Deposition Using Mesh and Jet Nebulizers During Noninvasive Ventilation in Healthy Subjects.

BACKGROUND In vivo deposition studies of aerosol administration during noninvasive ventilation (NIV) are scarce in the literature. The aim of this study was to compare radioaerosol pulmonary index and radioaerosol mass balance in the different compartments (pulmonary and extrapulmonary) of radio-tagged aerosol administered using vibrating mesh nebulizers and conventional jet nebulizers during N...

متن کامل

Breath-actuated nebulizer versus small-volume nebulizer: efficacy, safety, and satisfaction.

The breath-actuated nebulizer (BAN, AeroEclipse, Trudell Medical International, London, Ontario, Canada) has been available as an aerosol delivery option for several years. This small-volume jet nebulizer is primarily designed to generate aerosol during inspiration in response to the patient’s inspiratory flow triggering the opening valve.1,2 Some studies report that BAN provides smaller partic...

متن کامل

Nebulizers: principles and performance.

Nebulizers have been used clinically for many years. Despite the increasing use of metered-dose inhalers and dry powder inhalers, it is likely that nebulizers will continue to be used in selected patients. A number of factors affect nebulizer performance, and these should be appreciated by clinicians who use these devices. Several new designs have recently become available that improve the perf...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Respiratory care

دوره 54 4  شماره 

صفحات  -

تاریخ انتشار 2009