A novel device for target controlled administration and reflection of desflurane – the Mirus™

نویسندگان

  • H Bomberg
  • M Glas
  • V H Groesdonk
  • M Bellgardt
  • J Schwarz
  • T Volk
  • A Meiser
چکیده

The Anaconda™ system is used to deliver inhalational sedation in the intensive care unit in mainland Europe. The new Mirus™ system also uses a reflector like the Anaconda; however, it also identifies end-tidal concentrations from the gas flow, injects anaesthetics during early inspiration, controls anaesthetic concentrations automatically, and can be used with desflurane, which is not possible using the Anaconda. We tested the Mirus with desflurane in the laboratory. Compared with an external gas monitor, the bias (two standard deviations) of the end-tidal concentration was 0.11 (0.29)% volume. In addition, automatic control was reasonable and maximum concentration delivered was 10.2%, which was deemed to be sufficient for clinical use. Efficiency was > 80% and was also deemed to be acceptable, but only when delivering a low concentration of desflurane (≤ 1.8%). By modifying the reflector, we improved efficiency up to a concentration of 3.6%. The Mirus appears to be a promising new device for long-term sedation with desflurane on the intensive care unit, but efficiency must be improved before routine clinical use becomes affordable.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

AnaConDa™ and Mirus™ for intensive care sedation, 24 h desflurane versus isoflurane in one patient.

INTRODUCTION With the AnaConDa™ system, inhalational sedation in the intensive care unit has become popular. The device can be used with common intensive care unit ventilators and is inserted between the Y-piece and the patient. Liquid isoflurane or sevoflurane are delivered by a syringe pump. 90 % of anesthetic exhaled by the patient is absorbed by a reflector and resupplied during the next in...

متن کامل

The target concentration of remifentanil to suppress the hemodynamic response to endotracheal intubation during inhalational induction with desflurane

BACKGROUND Anesthesia induction with desflurane is troublesome because of the frequent sympathetic hyperactivity during desflurane administration. We thought that a low concentration of desflurane combined with a target-controlled infusion (TCI) of remifentanil would eliminate the desflurane-related complications and provide hemodynamic stability during desflurane induction. An up-and-down stud...

متن کامل

Effect-site concentration of remifentanil for smooth inhalational induction with desflurane

Objective To determine the effect-site concentration (Ce) of remifentanil target-controlled infusion required for a smooth inhalational induction without airway irritation using desflurane in a stepwise incremental manner for 50% of patients (EC50) and 95% of patients (EC95). Methods Patients with an American Society of Anesthesiologists physical status I and II, aged 19-60 years undergoing ele...

متن کامل

Poly (methacrylic acid-co-acrylic acid)-grafted polyvinylpyrrolidone coated Magnetic nanoparticles as a pH-responsive magnetic Nano-carrier for controlled delivery of antibiotics

Objective(s): Pharmaceutical industries are leading to improved medications that can target diseases more effectively and precisely. Researchers have intended to reformulate drugs so that they may be more safely used in human body. The more targeted a drug is, the lower its chance of triggering drug resistance, a cautionary concern surrounding the use of broad-spectrum antibiotics. The aim of t...

متن کامل

The Cell Survival of F10B16 Melanoma and 4T1 Breast Adenocarcinoma Irradiated to Gamma Radiation Using the MTT Assay Based on Two Different Calculation Methods

Background: Various MTT assay methods are proposed to obtain the cell sur- vival parameters.Objective: Determining the survival curve characteristics of two cancerous cells of interest based on a common and a novel MTT assay method after exposing them to ionizing radiation.Method: A common and a novel MTT assay method were used and compared for obtaining the F10B16 melanoma and 4T1 breast adeno...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 69  شماره 

صفحات  -

تاریخ انتشار 2014