In vivo human corneal hydration control dynamics: a new model.

نویسندگان

  • M T Odenthal
  • C P Nieuwendaal
  • H W Venema
  • J Oosting
  • J H Kok
  • A Kijlstra
چکیده

PURPOSE To introduce a new model describing human in vivo corneal deswelling after hypoxic contact lens wear, based on a damped harmonic oscillator, which can describe an overshoot in corneal deswelling, to compare this new model with the currently used exponential model, and also to test whether a diurnal variation in baseline corneal thickness exists that would have to be taken into consideration when calculating corneal deswelling curves. METHODS In nine healthy young adults, corneal thickness was measured every 30 minutes for 11.5 hours on average using modified optical pachometry (natural test). On another day, corneal deswelling was monitored for 11.1 hours on average after 2 hours of hypoxic contact lens wear (stress test). The damped harmonic oscillator model and the exponential model were used to calculate best-fitting deswelling curves. Natural test data were analyzed for the presence of a trend. Goodness of fit of the curves to the experimental data was analyzed using the F test. RESULTS In 82% of the deswelling curves the new damped harmonic oscillator model provided a better fit to the data than the exponential model (P < 0.05). An average overshoot in corneal thickness recovery of 5 microm (range, 0-11 microm) was found. In 50% of the natural tests significant trends were found, without any consistent similarities. The overshoot could not be explained by these trends. CONCLUSIONS The new damped harmonic oscillator model describes corneal deswelling after hypoxic contact lens wear more accurately than the exponential model. No consistent diurnal variation could be demonstrated.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A structural model for the in vivo human cornea including collagen-swelling interaction.

A structural model of the in vivo cornea, which accounts for tissue swelling behaviour, for the three-dimensional organization of stromal fibres and for collagen-swelling interaction, is proposed. Modelled as a binary electrolyte gel in thermodynamic equilibrium, the stromal electrostatic free energy is based on the mean-field approximation. To account for active endothelial ionic transport in ...

متن کامل

Human Gait Control Using Functional Electrical Stimulation Based on Controlling the Shank Dynamics

Introduction: Efficient gait control using Functional Electrical Stimulation (FES) is an open research problem. In this research, a new intermittent controller has been designed to control the human shank movement dynamics during gait. Methods: In this approach, first, the three-dimensional phase space was constructed using the human shank movement data recorded from the healthy subjects. Then...

متن کامل

Substrates for Expansion of Corneal Endothelial Cells towards Bioengineering of Human Corneal Endothelium

Corneal endothelium is a single layer of specialized cells that lines the posterior surface of cornea and maintains corneal hydration and corneal transparency essential for vision. Currently, transplantation is the only therapeutic option for diseases affecting the corneal endothelium. Transplantation of corneal endothelium, called endothelial keratoplasty, is widely used for corneal endothelia...

متن کامل

Variations of the Normal Human Limbal Stem Cells Detected by In Vivo Confocal Microscopy

Background  To report normal variations of the limbal structures using in vivo laser scanning confocal microscopy. Methods: This was a retrospective study of fourteen eyes from 11 healthy individuals. Confocal imaging of cornea and limbus was performed using Heidelberg Retina Tomograph III Rostock Corneal Module. Results: The typical structure of the palisades of Vogt (POV) was detected ...

متن کامل

Monitoring of rabbit cornea response to dehydration stress by optical coherence tomography.

PURPOSE To evaluate the application of optical coherence tomography (OCT) for continuous noninvasive monitoring and quantification of the dynamics of corneal response after exposure of the cornea to dehydrating stress. METHODS The changes in central corneal thickness (CCT) and scattering properties of the cornea were monitored with OCT in rabbit cornea in vivo after topical application of a g...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 40 2  شماره 

صفحات  -

تاریخ انتشار 1999