Nash Problem for Stable Toric Varieities

نویسندگان

  • PETER PETROV
  • Peter Petrov
چکیده

The main result of this paper is the proof of Nash conjecture for stable toric varieties. We also introduce Nash problem for pairs and prove it in the case of pairs (X, Y ) of toric variety X and a proper closed T -invariant subset Y , containing Sing(X).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The GIT-stability of Polarised Varieties via discrepancy

We study the GIT stability of polarised varieities, in the language of the discrepancy of singularities, developed along the Mori Program. We give a new geometric numerical invariant of polarised varities, which is directly related to the discrepancy of singularities, whose negativity destabilises the polarised varieties. We relate this new invariant to the invariant which was used in J.Shah’s ...

متن کامل

Toric Geometry and the Semple-nash Modification

This paper proposes some material towards a theory of general toric varieties without the assumption of normality. Their combinatorial description involves a fan to which is attached a set of semigroups subjected to gluing-up conditions. In particular it contains a combinatorial construction of the blowing up of a sheaf of monomial ideals on a toric variety. In the second part this is used to s...

متن کامل

Toric Geometry and the Semple-nash Modification

This paper proposes some material towards a theory of general toric varieties without the assumption of normality. Their combinatorial description involves a fan to which is attached a set of semigroups subjected to gluing-up conditions. In particular it contains a combinatorial construction of the blowing up of a sheaf of monomial ideals on a toric variety. In the second part this is used to s...

متن کامل

Toric Iol Power Calculation

Obviously, toric lenses have to remain in stable positions after implantation bearing in mind that for every 10 degrees of misalignment, there is one third loss of toric correction. While some time ago this was still a problem, toric IOLs of today are significantly less affected by lens rotation. Another disturbing issue with toric lenses has also been fixed in the meantime: according to a new ...

متن کامل

Reverse Optic Capture to Stabilize a Toric Intraocular Lens

PURPOSE To describe a technique for stabilizing a rotationally unstable toric intraocular lens (IOL). METHOD Case report and literature review. RESULTS Surgical technique and long-term follow-up for a patient who underwent repositioning and stabilization of a mobile 1-piece acrylic toric IOL using reverse optic capture (ROC) are described. This patient presented with early, more than 70° of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006