Dosimetric advantage of using 6 MV over 15 MV photons in conformal therapy of lung cancer: Monte Carlo studies in patient geometries
نویسندگان
چکیده
Many lung cancer patients who undergo radiation therapy are treated with higher energy photons (15-18 MV) to obtain deeper penetration and better dose uniformity. However, the longer range of the higher energy recoil electrons in the low-density medium may cause lateral electronic disequilibrium and degrade the target coverage. To compare the dose homogeneity achieved with lower versus higher energy photon beams, we performed a dosimetric study of 6 and 15 MV three-dimensional (3D) conformal treatment plans for lung cancer using an accurate, patient-specific dose-calculation method based on a Monte Carlo technique. A 6 and 15 MV 3D conformal treatment plan was generated for each of two patients with target volumes exceeding 200 cm(3) on an in-house treatment planning system in routine clinical use. Each plan employed four conformally shaped photon beams. Each dose distribution was recalculated with the Monte Carlo method, utilizing the same beam geometry and patient-specific computed tomography (CT) images. Treatment plans using the two energies were compared in terms of their isodose distributions and dose-volume histograms (DVHs). The 15 MV dose distributions and DVHs generated by the clinical treatment planning calculations were as good as, or slightly better than, those generated for 6 MV beams. However, the Monte Carlo dose calculation predicted increased penumbra width with increased photon energy resulting in decreased lateral dose homogeneity for the 15 MV plans. Monte Carlo calculations showed that all target coverage indicators were significantly worse for 15 MV than for 6 MV; particularly the portion of the planning target volume (PTV) receiving at least 95% of the prescription dose (V(95)) dropped dramatically for the 15 MV plan in comparison to the 6 MV. Spinal cord and lung doses were clinically equivalent for the two energies. In treatment planning of tumors that abut lung tissue, lower energy (6 MV) photon beams should be preferred over higher energies (15-18 MV) because of the significant loss of lateral dose equilibrium for high-energy beams in the low-density medium. Any gains in radial dose uniformity across steep density gradients for higher energy beams must be weighed carefully against the lateral beam degradation due to penumbra widening.
منابع مشابه
3-Dimensional conformal radiotherapy versus intensity modulated radiotherapy for localized prostate cancer: Dosimetric and radiobiologic analysis
Background: To analyze the dosimetric and radio biologic advantages between intensity modulated radiotherapy (IMRT) and 3 dimensional conformal radiotherapy (3DCRT) and selection of optimal photon energy for IMRT treatments. Material and methods: 24 patients with localized prostate carcinoma were planned for 3DCRT and IMRT techniques. Radiation dose of 54 Gy with 2 Gy/fraction, was planned to ...
متن کاملDosimetric influence of Flattening Filter (FF) and Flattening Filter Free (FFF) 6 and 10 MV photon beams on Volumetric Modulated Arc Therapy (VMAT) planning in case of prostate carcinoma
Background: In the treatment of prostate cancer, radiotherapy is the potential to increase second primary cancers such as bladder and rectal cancers. The reasons for this potential are more monitor units (MUs), therefore a larger total body dose because of leakage radiation, a bigger volume of normal tissue is exposed to lower radiation doses. This study was designed to compare the integral dos...
متن کاملA Monte Carlo simulation and dosimetric verification of physical wedges used in radiation therapy
Background: The presence of a wedge filter in the beam trajectory can modify the beam quality and cause some changes in the dosimetry parameters which are usually difficult to be measured directly and accurately. Material and Methods: In this study the MCNP-4C Monte Carlo code was used to simulate the 9 MV photon beam generated by a linear accelerator. Upon getting a good agreement bet...
متن کاملEstimation of Dosimetric Parameters based on KNR and KNCSF Correction Factors for Small Field Radiation Therapy at 6 and 18 MV Linac Energies using Monte Carlo Simulation Methods
Background: Estimating dosimetric parameters for small fields under non-reference conditions leads to significant errors if done based on conventional protocols used for large fields in reference conditions. Hence, further correction factors have been introduced to take into account the influence of spectral quality changes when various detectors are used in non-reference conditions at differen...
متن کاملIntermediate Megavoltage Photon Beams for Improved Lung Cancer Treatments
The goal of this study is to evaluate the effects of intermediate megavoltage (3-MV) photon beams on SBRT lung cancer treatments. To start with, a 3-MV virtual beam was commissioned on a commercial treatment planning system based on Monte Carlo simulations. Three optimized plans (6-MV, 3-MV and dual energy of 3- and 6-MV) were generated for 31 lung cancer patients with identical beam configurat...
متن کامل