Taste and Odour Disturbances in Pediatric Patients Undergoing IV Flush with Normal Saline Administered by Prefilled or Freshly Prepared Syringes: Randomized Single-Blind Study.
نویسندگان
چکیده
BACKGROUND Previous studies have reported the occurrence of taste and odour disturbances among patients undergoing IV flush with prefilled syringes of 0.9% sodium chloride (normal saline [NS]). These disturbances have been attributed to the leaching of volatile substances into the NS from the plastic of the syringe. To date, there have been no studies comparing the occurrence of taste and odour disturbances with different NS preparations. OBJECTIVE To compare the occurrence of taste and odour disturbances in pediatric patients undergoing IV flush with commercially available prefilled NS syringes and NS syringes prepared fresh daily. METHODS Patients aged 6 to 18 years who underwent routine flushing of central or peripheral IV tubing were asked to participate in this follow-up randomized single-blind study. Flushing was performed with NS from BD PosiFlush 10-mL sterile prefilled syringes or NS transferred from a polyolefin bag (Baxter AVIVA) to a polypropylene syringe and stored for a maximum of 12 h before use. RESULTS Fifty pediatric patients (mean age ± standard deviation 13.4 ± 3.8 years) who had undergone flushing of IV tubing with NS were interviewed. Taste or odour disturbances were reported by 18 (72%) of the 25 patients who underwent flushing with NS from a prefilled syringe, whereas only 1 (4%) of the 25 who underwent flushing with NS from a freshly prepared syringe experienced such disturbances (p < 0.001). CONCLUSIONS There were significant differences in taste and odour disturbances experienced by patients who underwent IV flush with commercial prefilled NS syringes and freshly prepared NS syringes.
منابع مشابه
Taste and/or Odour Disturbances in Pediatric Patients Undergoing IV Flush with Normal Saline Administered by Prefilled Syringe.
BACKGROUND At the Children's Hospital of Eastern Ontario, more than 6000 inpatients per year undergo IV saline flushes by prefilled syringe to assess and maintain patency of IV tubing. In studies involving adults, it has been reported that volatile substances may leach from syringe materials into the saline, leading to taste and/or odour disturbances. OBJECTIVE To determine the incidence of t...
متن کاملExperience of unpleasant sensations in the mouth after injection of saline from prefilled syringes
BACKGROUND Nurses at The Norwegian Radium Hospital have reported that some patients notice an unpleasant smell or taste in accordance with flushing of intravenous lines with commercially available prefilled syringes. We have conducted a study in healthy volunteers to investigate the occurrence, consistency and intensity of this phenomenon. METHODS A randomised, blinded, crossover study compar...
متن کاملErrors with prefilled saline syringes when used to reconstitute or dilute medications.
In 2006, ISMP (US) reported that prefilled saline syringes were being used for reconstitution or dilution of medications, with the medication being withdrawn from the vial back into the syringe. 1 ISMP alerted practitioners to the increased risk of medication error if syringes used in this way were not appropriately relabelled. This problem can be of particular concern if a high-alert medicatio...
متن کاملThe effects of Vitamin C on Inflammatory Markers and Atrial Fibrillation in Patients Undergoing Coronary Artery Bypass Surgery in Bushehr Heart Center: A Randomized Controlled Clinical Trial
Background: Coronary artery bypass graft surgery (CABG) with cardiopulmonary bypass pump may cause systemic inflammatory reactions by releasing cytokines which leads to multiple organ failure. Vitamin C has anti-inflammatory and antioxidant properties. The study aimed to determine the effect of vitamin C on inflammatory markers and atrial fibrillation in patients undergoing CABG. Materials and ...
متن کاملNotes from the Field: Hepatitis C Transmission from Inappropriate Reuse of Saline Flush Syringes for Multiple Patients in an Acute Care General Hospital — Texas, 2015
In October 2015, the Texas Department of State Health Services (DSHS) was notified that a hospital telemetry unit nurse had been reusing saline flush prefilled syringes in the intravenous (IV) lines of multiple patients, a risk factor for patient-to-patient transmission of bloodborne pathogens (1).* This practice was discovered through an investigation undertaken by the hospital after the nurse...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Canadian journal of hospital pharmacy
دوره 67 5 شماره
صفحات -
تاریخ انتشار 2014