Contrast Media Injector Technology - Renal Safety During Coronarography
نویسندگان
چکیده
AIM This study sought to assess whether the volume and osmolarity of contrast media (CM) influences the occurrence of contrast induced nephropathy (CIN) following coronarography procedure. CIN can be defined as an increase in the serum concentration of creatinine greater than a 25% from baseline during the period of 12 to 48 hours after the administration of radiocontrast media. MATERIAL AND METHODS We examined 100 patients without diabetes with serum creatinine concentration from 45 mmol/l to 141 mmol/l and 100 patients with diabetes with serum creatinine concentration from 46 mmol/l to 161 mmol/l who underwent coronary angiography. During procedure they received iso-osmolar contrast medium, Visipaque 320 (iodixanol-320), for group without diabetes from 40 to 340 ml and for group with diabetes from 49 to 310 ml. RESULTS CIN occurred in 27 (13,5%) of the 200 study patients. There was a trend toward higher prevalence of CIN (16% vs.11%, p = 0.086) in the diabetic group compared with the non-diabetic group. Patient with diabetes received less contrast media, they are younger but number patients with CIN are higher. CONCLUSION Increasing contrast media dose is associated with the occurrence of CIN following coronarography. But, another risk factors like diabetes mellitus, old age, male sex and preexisting kidney disease have influence of developing CIN after coronarography.
منابع مشابه
Peripheral diagnostic and interventional procedures using an automated injection system for carbon dioxide (CO2): case series and learning curve
INTRODUCTION The administration of iodinated contrast media in doses sufficient for diagnosis and procedural guidance, when coincident with renal insufficiency, presents a considerable risk of exacerbating and hastening renal failure. Carbon dioxide has been proposed in the past as an alternative, but only recently dedicated injection systems have become available. We aimed to review our ongoin...
متن کاملComparison of Safety of Radial and Femoral Approaches for Coronary Catheterization in Interventional Cardiology
BACKGROUND The femoral approach has been the preferably used access in interventional cardiology as well for coronary diagnostics as for percutaneous coronary intervention, being perceived as easy and facilitating quick access with relatively low risk. Due to the results of the latest studies, however, the radial approach has become increasingly popular. The aim of this study was a safety analy...
متن کاملContrast medium administration and image acquisition parameters in renal CT angiography: what radiologists need to know.
Over the last decade, exponential advances in computed tomography (CT) technology have resulted in improved spatial and temporal resolution. Faster image acquisition enabled renal CT angiography to become a viable and effective noninvasive alternative in diagnosing renal vascular pathologies. However, with these advances, new challenges in contrast media administration have emerged. Poor synchr...
متن کاملEvaluation of the usefulness of coronary catheters and 4 Fr insertion sets for transradial access coronarography in comparison with catheters and 5 Fr sets
INTRODUCTION Application of transradial arterial access during coronarography, besides pain, means faster patient mobilization and fewer complications. During those procedures, vascular sheaths and 5/6 Fr catheters, and lately 4 Fr catheters, are used. AIM To assess the usefulness of 4 Fr catheters and sheaths in comparison to 5 Fr in diagnostic coronarography. MATERIAL AND METHODS In the p...
متن کاملRenal fornix rupture following diagnostic coronarography.
A 31-year-old man with an uneventful medical history presented at the emergency department with complaints of exercise-related chest pain for 3 weeks. ECG showed ST-elevations in the inferior leads. A diagnostic coronarography was performed and showed multivessel coronary stenosis. During this procedure 200 ml of a nonionic, low-osmolality monomeric contrast agent (Iomeron 350) and 1250 ml of i...
متن کامل