Unlaminated Gafchromic Ebt3 Film for Ultraviolet Radiation Monitoring.
نویسندگان
چکیده
Measurement of ultraviolet (UV) radiation is important for human health, especially with the expanded usage of short wavelength UV for sterilization purposes. This work examines unlaminated Gafchromic EBT3 film for UV radiation monitoring. The authors exposed the film to select wavelengths in the UV spectrum, ranging from 207 to 328 nm, and measured the change in optical density. The response of the film is wavelength dependent, and of the wavelengths tested, the film was most sensitive to 254 nm light, with measurable values as low as 10 µJ/cm2. The film shows a dose-dependent response that extends over more than four orders of magnitude. The response of the film to short wavelength UV is comparable to the daily safe exposure limits for humans, thus making it valuable as a tool for passive UV radiation monitoring.
منابع مشابه
Intensities of Incident and Transmitted Ultraviolet-A Rays through Gafchromic Films
Gafchromic films have been applied to X-ray dosimetry in diagnostic radiology. To correct nonuniformity errors in Gafchromic films, X-rays in the double-exposure technique can be replaced with ultraviolet (UV)-A rays. Intensities of the incident and transmitted UV-A rays were measured. However, it is unclear whether the chemical color change of Gafchromic films affects the UV-A transmission int...
متن کاملComparing three UV wavelengths for pre‐exposing Gafchromic EBT2 and EBT3 films
Gafchromic films are used for X-ray dose measurements during diagnostic examinations and have begun to be used for three-dimensional X-ray dose measurements using the high-resolution characteristics of Gafchromic films for computed tomography. However, the problem of unevenness in Gafchromic film active layers needs to be resolved. Double exposures using X-rays are performed during therapeutic ...
متن کاملA Feasibility Study of IMRT of Lung Cancer Using Gafchromic EBT3 Film
Background: Intensity modulated radiation therapy (IMRT) is an advanced method for delivery of three dimensional therapies, which provides optimal dose distribution with giving multiple nonuniform fluency to the patient. The complex dose distribution of IMRT should be checked to ensure that the accurate dose is delivered. Today, film dosimetry is a powerful tool for radiotherapy treatment Quali...
متن کاملCorrection of nonuniformity error of Gafchromic EBT2 and EBT3
This study investigates an X-ray dose measurement method for computed tomography using Gafchromic films. Nonuniformity of the active layer is a major problem in Gafchromic films. In radiotherapy, nonuniformity error is reduced by applying the double-exposure technique, but this is impractical in diagnostic radiology because of the heel effect. Therefore, we propose replacing the X-rays in the d...
متن کاملImpact of region of interest size and location in Gafchromic film dosimetry
Introduction: Accurate film dosimetry requires careful consideration of sources of uncertainty. Some of the sources of uncertainty are dependent on the size and location of region of interest (ROI), especially in small fields. Avoiding the penumbra is often a reason for using a small ROI. In contrast, choosing very small ROIs may increase uncertainty due to the reduction of th...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Radiation protection dosimetry
دوره 176 4 شماره
صفحات -
تاریخ انتشار 2017