Use of an inspiratory impedance threshold device on a facemask and endotracheal tube to reduce intrathoracic pressures during the decompression phase of active compression-decompression cardiopulmonary resuscitation.

نویسندگان

  • Patrick Plaisance
  • Christian Soleil
  • Keith G Lurie
  • Eric Vicaut
  • Laurent Ducros
  • Didier Payen
چکیده

INTRODUCTION Use of an inspiratory impedance threshold device (ITD) significantly increases coronary perfusion pressures and survival in patients ventilated with an endotracheal tube (ETT) during active compression-decompression cardiopulmonary resuscitation. We tested the hypothesis that the ITD could lower intratracheal pressures when attached to either a facemask or ETT. METHODS An active and sham ITD were randomly applied first to a facemask and then to an ETT during active compression-decompression cardiopulmonary resuscitation in 13 out-of-hospital cardiac arrest patients in a randomized, double-blinded, prospective clinical trial. The compression-to-bag-valve ventilation ratio was 15:2. Airway pressures (surrogate for intrathoracic pressure) were measured with a pressure transducer. A sham and an active ITD were used for 1 min each in a randomized order, first on a facemask and then on an ETT. Statistical analyses were made using Friedman's and Wilcoxon's rank-sum tests. RESULTS For the primary end point, mean +/- sd maximum negative intrathoracic pressures (mm Hg) during the decompression phase of cardiopulmonary resuscitation were -1.0 +/- 0.73 mm Hg with a sham vs. -4.6 +/- 3.7 mm Hg with an active ITD on the facemask (p = .003) and -1.3 +/- 1.3 mm Hg with a sham ITD vs. -7.3 +/- 4.5 mm Hg with an active ITD on an ETT (p = .0009). Decompression phase airway pressures with the facemask and ETT were not statistically different. CONCLUSIONS Use of an active ITD attached to a facemask or an ETT resulted in a significantly lower negative intratracheal pressure during the decompression phase of active compression-decompression cardiopulmonary resuscitation when compared with controls. Airway pressures with an ITD on either a facemask or ETT were similar. The ITD-facemask combination was practical and enables rapid deployment of this life-saving technology.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Use of an inspiratory impedance threshold valve during cardiopulmonary resuscitation: a progress report.

Building upon studies on the mechanism of active compression-decompression (ACD) cardiopulmonary resuscitation, a new inspiratory impedance threshold valve has been developed to enhance the return of blood to the thorax during the decompression phase of CPR. Use of this device results in a greater negative intrathoracic pressure during chest wall decompression. This leads to improved vital orga...

متن کامل

Clinical Investigations Clinical evaluation of an inspiratory impedance threshold device during standard cardiopulmonary resuscitation in patients with out-of-hospital cardiac arrest*

An inspiratory impedance threshold device (ITD) has recently been demonstrated to enhance vital organ perfusion and neurologically intact survival rates in animals in cardiac arrest during standard cardiopulmonary resuscitation (CPR) (1– 4). The ITD is a small, 35-mL device that can attach to a variety of airway adjuncts, including a facemask and endotracheal tube (Fig. 1). By selectively imped...

متن کامل

Evaluation of a prototypic inspiratory impedance threshold valve designed to enhance the efficiency of cardiopulmonary resuscitation.

OBJECTIVE Assess a prototype inspiratory impedance threshold valve (ITV) designed to enhance vital organ circulation during standard and active compression/decompression cardiopulmonary resuscitation (CPR). BACKGROUND The ITV attaches to commonly used airway assist devices and decreases intrathoracic pressure during the decompression (chest recoil) phase of CPR by creating a vacuum within the...

متن کامل

Utilization of a model lung system to assess the effects of an inspiratory impedance threshold valve on the relationship between active decompression and intra-thoracic pressure.

Use of an inspiratory impedance valve has recently been shown to increase the efficacy of standard and active compression-decompression cardiopulmonary resuscitation. We evaluated the effects of a prototypic impedance valve on the relationship between the active decompression and intra-thoracic pressure using a mechanical model lung system. Intermittent impedance to inspiratory flow of respirat...

متن کامل

Inspiratory impedance during active compression-decompression cardiopulmonary resuscitation: a randomized evaluation in patients in cardiac arrest.

BACKGROUND Blood pressure is severely reduced in patients in cardiac arrest receiving standard cardiopulmonary resuscitation (CPR). Although active compression-decompression (ACD) CPR improves acute hemodynamic parameters, arterial pressures remain suboptimal with this technique. We performed ACD CPR in patients with a new inspiratory threshold valve (ITV) to determine whether lowering intratho...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Critical care medicine

دوره 33 5  شماره 

صفحات  -

تاریخ انتشار 2005