Experimental third ventriculostomy performed using endovascular surgical techniques and their adaptation to percutaneous intradural neuronavigation: proof of concept cadaver study.

نویسندگان

  • Michael B Horowitz
  • Kamal Ramzipoor
  • Ajit Nair
  • Susan Miller
  • George Rappard
  • Richard Spiro
  • Phillip Purdy
چکیده

OBJECTIVE Endoscopic third ventriculostomy has developed into a therapeutic alternative to shunting for the management of carefully selected patients with primarily noncommunicating hydrocephalus. This procedure, however, requires a general anesthetic and necessitates violation of the brain parenchyma and manipulation near vital neural structures to access the floor of the third ventricle. Using two cadavers and off-the-shelf angiographic catheters, we sought to determine whether it was possible to navigate a catheter, angioplasty balloon, and stent percutaneously through the subarachnoid space from the thecal sac into the third ventricle so as to perform a third ventriculostomy from below. METHODS Using biplane angiography and off-the-shelf angiographic catheters along with angioplasty balloons and stents, we were able to pass a stent coaxially from the thecal sac to and across the floor of the third ventricle so as to achieve a third ventriculostomy from below. RESULTS Coaxial catheter techniques allowed for the percutaneous insertion of a stent across the floor of the third ventricle. Ventriculostomy was confirmed by injecting contrast medium into the lateral ventricle and seeing it pass through the stent and into the chiasmatic cistern. CONCLUSION We describe the performance of third ventriculostomies in two cadavers by use of the new concept of percutaneous intradural neuronavigation. This procedure may obviate the need for general anesthetic and minimize the potential for brain and vascular injury, especially if ultimately combined with magnetic resonance fluoroscopy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Obstructive Hydrocephalus Caused by an Unruptured Arteriovenous Malformation Successfully Treated by Endoscopic Third Ventriculostomy After Shunt Dysfunction.

The authors report on a patient harbouring an unruptured cortical arteriovenous malformation (AVM), who had presented with obstructive hydrocephalus due to compression of the cerebral aqueduct by a large venous varix. A ventriculoperitoneal (VP) shunt was inserted in emergency. Due to its large volume, the AVM was not referred for treatment and a follow-up policy was chosen. After the second VP...

متن کامل

Nontraumatic aneurysm rupture following an endoscopic third ventriculostomy and ventricular drainage: Case report of a rare complication

BACKGROUND Although endoscopic third ventriculostomy is a safe procedure, the authors report a case of aneurysmal subarachnoid hemorrhage as an unusual and serious complication of an endoscopic third ventriculostomy and ventricular drainage. CASE DESCRIPTION A 60-year-old male presented with obstructive hydrocephalus caused by midbrain tumors was admitted to our hospital. Endoscopic third ven...

متن کامل

Endoscopic third ventriculostomy in treatment of hydrocephalus

INTRODUCTION Endoscopic third ventriculostomy (ETV) is a minimally invasive method of treatment of obstructive hydrocephalus (HCP). AIM To investigate perioperative and intraoperative difficulties, failures and complications of ETV. MATERIAL AND METHODS Seventy-three procedures of ETV were conducted in our department in the last 5 years on 69 patients with HCP of different etiology. In 4 pa...

متن کامل

Real-time Video-Streaming to Surgical Loupe Mounted Head-Up Display for Navigated Meningioma Resection.

AIM Wearable technology interfaces with normal human movement and function, thereby enabling more efficient and adaptable use.We developed a wearable display system for use with intra-operative neuronavigation for brain tumor surgery. MATERIAL AND METHODS The Google glass head-up display system was adapted to surgical loupes with a video-streaming integrated hardware and software device for d...

متن کامل

Robot-assisted pharyngeal and laryngeal microsurgery: results of robotic cadaver dissections.

OBJECTIVES/HYPOTHESIS Robotic surgery has significant potential in pharyngeal and microlaryngeal surgery. We demonstrate the use of a surgical robot in pharyngeal and microlaryngeal surgery in a cadaver. STUDY DESIGN Six experimental surgical dissections, modeled after commonly performed pharyngeal and microlaryngeal procedures, were performed in a cadaver with a commercially available surgic...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Neurosurgery

دوره 53 2  شماره 

صفحات  -

تاریخ انتشار 2003