Retained Foreign Body in Transplanted Liver
نویسندگان
چکیده
Liver transplantation is a technically complex and long surgical procedure. A large quantity of various materials such as catheters, sutures, needles and clips are frequently used during the procedure. These materials may enter in the liver from the vascular or biliary orifices inadvertently. A 50-year-old patient who had hepatic failure due to HBV underwent a deceased-donor liver transplantation. The deceased donor was a 75-year-old HbsAg(+) man. The recipient had subfebrile fever and leukocytosis post-operatively. A control computed tomography revealed a cuneiform ischemic area, and a foreign body inside the right anterior portal vein branch proximal to this ischemic region. A 10-F Nelaton catheter, 5-cm long, was removed from the portal vein by surgery. Retrospectively, we understood that the portal vein was cut during the back-table procedure and the portal vein catheter was replaced with a larger one for better irrigation. Most probably, the original catheter was cut together with the portal vein, and the tip of the catheter was retained in the portal system and migrated into the liver. As far as we know, such a complication of liver transplantation has never been described previously.
منابع مشابه
Gossypiboma: a case report
Gossypiboma, an infrequent surgical complication, is a mass lesion due to a retained surgical sponge surrounded by foreign-body reaction. A 27-year-old lady presented with palpable abdominal mass five years after cesarean section. Retained foreign body was diagnosed radiologically and confirmed with operation. Retained foreign body should be in the differential diagnosis of any postoperative pa...
متن کاملPerfluoro-n-octane mimicking an intraocular foreign body
Retained intraocular foreign body (IOFB) is a major cause of visual loss following open globe injuries. Detecting the presence and accurate localization of IOFB in the setting of an open globe injury remains a challenge. There can be various mimics of intraocular IOFB on imaging including air, ocular calcifications, etc. Here, we describe a case of open globe injury wherein a retained perfluoro...
متن کاملمقایسه نتایج سونوگرافی با گرافی ساده گردن در شناسایی جسم خارجی مری سرویکال
Background: Detection of retained foreign bodies remains a significant problem in the emergency department. Foreign bodies can go undetected causing infectious complications ultrasonography is too inaccessible and expensive. The purpose of this study is comparison of ultrasonography with radiography for the detection of cervical esophageal foreign bodiesMethods: This cross-sectional study evalu...
متن کاملDelayed myelopathy secondary to stab wound with a retained blade tip within the laminae: case report.
Delayed neurologic deficit after a stab wound with a retained foreign body near the spinal canal is unusual, adequate radiological examination is fundamental in detecting retained foreign bodies, especially the CT scan, surgical extraction of the foreign body is the primary task and the surgical outcome is satisfactory. Here, we report a rare case of delayed myelopathy caused by spinal stenosis...
متن کامل25-Gauge Vitrectomy in Open Eye Injury with Retained Foreign Body
Purpose. Ocular trauma with retained foreign body is an important cause of visual impairment in working-age population. Clinical status impacts on the timing and planning of surgery. In the last year small gauge vitrectomy has become safer and more efficient, extending the range of pathologies successfully treated. Aims. To evaluate the safety and outcomes in patients with open eye injury with ...
متن کامل