Improving pulse oximetry accuracy by removing motion artifacts from photoplethysmograms using relative sensor motion: a preliminary study.
نویسندگان
چکیده
To expand applicability of pulse oximetry in low-acuity ambulatory settings, the impact of motion on extracted parameters as saturation (SpO2) and pulse rate (PR) needs to be reduced. We hypothesized that sensor motion relative to the skin can be used as an artifact reference in a correlation canceller to reduce motion artifacts in photoplethysmograms (PPGs), in order to improve SpO2 and PR measurements. This has been proven true in in vivo measurements, where forehead PPGs have been obtained while subjects are walking on a treadmill and relative sensor motion has been measured via self-mixing interferometry. By using relative motion in a normalized least mean square algorithm, the standard deviation of SpO2 and PR errors is on average reduced by 31 % and 13 %, respectively.
منابع مشابه
Improving pulse oximetry accuracy by removing motion artifacts from photoplethysmograms using relative sensor motion: preliminary study
To expand applicability of pulse oximetry in low-acuity ambulatory settings, the impact of motion on extracted parameters as saturation (SpO2) and pulse rate (PR) needs to be reduced. It is hypothesized that sensor motion relative to the skin can be used as an artifact reference in a correlation canceler to reduce motion artifacts in photoplethysmograms (PPGs), in order to improve SpO2 and PR m...
متن کاملReducing motion artifacts in photoplethysmograms by using relative sensor motion: phantom study.
Currently, photoplethysmograms (PPGs) are mostly used to determine a patient's blood oxygenation and pulse rate. However, PPG morphology conveys more information about the patient's cardiovascular status. Extracting this information requires measuring clean PPG waveforms that are free of artifacts. PPGs are highly susceptible to motion, which can distort the PPG-derived data. Part of the motion...
متن کاملImproving Pulse Rate Measurements during Random Motion Using a Wearable Multichannel Reflectance Photoplethysmograph
Photoplethysmographic (PPG) waveforms are used to acquire pulse rate (PR) measurements from pulsatile arterial blood volume. PPG waveforms are highly susceptible to motion artifacts (MA), limiting the implementation of PR measurements in mobile physiological monitoring devices. Previous studies have shown that multichannel photoplethysmograms can successfully acquire diverse signal information ...
متن کاملAssessment of simulated patient motion and its effect on myocardial perfusion SPECT using two reconstruction methods (Filtered Backprojection;FBP and Iterative method) [Persian]
Introduction: Motion of the patient during myocardial perfusion SPECT could potentially results in false perfusion defects. The effect of different reconstruction methods on these artifacts is not studied. Clarification of the relation between the extent, severity and duration of motion with the resultant artifacts may be helpful in designing special soft wares for motion correction. This...
متن کاملEvaluation of design parameters for a reflection based long-term pulse oximetry sensor
Pulse oximetry is a standard parameter for many years in clinical patient monitoring. There are also sensors that can be used at home. But all these sensors use the transmission based method to measure the oxygen saturation which require finger or ear clips that are uncomfortable and confining and therefore not fit for long-term monitoring. Sleep-related breathing disorders or breathing thin ai...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Advances in experimental medicine and biology
دوره 789 شماره
صفحات -
تاریخ انتشار 2013