OBJECTIVE This study was conducted to compare the relative, clinical intraocular dose distribution for palladium-103 (103Pd) versus iodine-125 (125I) ophthalmic plaque radiation therapy. METHODS Preoperative comparative radiation dosimetry was performed to evaluate 319 consecutive uveal melanomas treated between 2006 and 2012. RESULTS There were 68 (21.3 %) anterior (iris and/or ciliary body) and 251 (78.7 %) choroidal melanomas examined in this study. According to AJCC staging, 7th edition, 146 (45.8 %) were T1, 126 (39.5 %) T2, 40 (12.5 %) T3, and 7 (2.2 %) T4. All were prescribed an equivalent tumor-apex dose. When compared to 125I, 103Pd was associated with a mean 41.9 % lower radiation dose to the opposite eye wall (p < 0.001), 12.7 % to the lens center (p < 0.001), 7.5 % to the optic disc (p = 0.008), and a 3.8 % decrease to the fovea (p = 0.034). However, subgroup analysis of smaller (T1-staged) tumors showed greater dose reductions to normal ocular structures compared to larger (T4-staged) tumors. Tumor and therefore plaque location also affected intraocular dose distribution. For example, palladium-103-related dose reductions to the fovea, optic nerve, and opposite eye wall were significantly greater for iris and ciliary body tumors compared to posterior choroidal melanomas (p < 0.001). After comparative dosimetry, 98.7 % (n = 315/319) were treated with 103Pd. CONCLUSION Preoperative comparative radiation dosimetry was performed for a large cohort of patients with uveal melanoma. It influenced radionuclide selection, offered an opportunity for radiation sparing of critical vision-related intraocular structures, and typically increased radiation within the tumors.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dosimetry Comparison of Water Phantom and Complete Eye Definition for 125I and 103Pd Brachytherapy Plaques

Introduction: In this paper, by complete definition of human eye containing the various parts and their materials, the difference between this model and a homogeneous water phantom are compared for two ophthalmic plaques using 125I and 103Pd. Material and methods: The simulation of the two phantoms were performed in the MCNP-4C code and by using the geometry of a three-dimensional eye, differen...

متن کامل

The American Brachytherapy Society consensus guidelines for plaque brachytherapy of uveal melanoma and retinoblastoma.

PURPOSE To present the American Brachytherapy Society (ABS) guidelines for plaque brachytherapy of choroidal melanoma and retinoblastoma. METHODS AND MATERIALS An international multicenter Ophthalmic Oncology Task Force (OOTF) was assembled to include 47 radiation oncologists, medical physicists, and ophthalmic oncologists from 10 countries. The ABS-OOTF produced collaborative guidelines, bas...

متن کامل

Long term visual outcome of radiated uveal melanomas in eyes eligible for randomisation to enucleation versus brachytherapy.

AIMS To determine the long term visual outcome of patients who were eligible for randomisation to enucleation versus brachytherapy in a US collaborative ocular melanoma study (COMS) but were treated with either helium ion or 125I radioactive plaque therapy. METHOD A retrospective analysis was performed of 426 ciliochoroidal melanomas that met COMS inclusion criteria for randomisation to enucl...

متن کامل

Ocular brachytherapy dosimetry for 103Pd and 125I in the presence of gold nanoparticles: a Monte Carlo study

The aim of the present Monte Carlo study is to evaluate the variation of energy deposition in healthy tissues in the human eye which is irradiated by brachytherapy sources in comparison with the resultant dose increase in the gold nanoparticle (GNP)-loaded choroidal melanoma. The effects of these nanoparticles on normal tissues are compared between 103Pd and 125I as two ophthalmic brachytherapy...

متن کامل

Long-Term Followup Comparing Two Treatment Dosing Strategies of 125I Plaque Radiotherapy in the Management of Small/Medium Posterior Uveal Melanoma

Objective. To investigate the efficacy of two different dosing strategies of radioactive iodine-125 ((125)I) in the management of small- and medium-sized posterior uveal melanoma. Patients and Methods. The medical records of consecutive patients with choroidal melanomas between 1.5 and 5.0 mm in apical height treated initially with (125)I plaque radiotherapy were reviewed. Patients were treated...