Computerised tomography performance.

نویسنده

  • P Hammersberg
چکیده

Generally, computerised tomography (CT) is an X-ray based non-destructive testing method that was developed for medical purposes in the seventies and introduced for industrial applications during the eighties. CT produces maps of the X-ray linear attenuation coefficient of an object’s interior; presented either as cross section images (two-dimensional CT) or as volume information (three-dimensional CT). The linear attenuation coefficient is the fraction of X-ray photons absorbed or scattered per unit length as the ray propagates through an object. The linear attenuation coefficient depends on the X-ray photon energy, and both object density and atomic composition. Most industrial CT systems are equipped with conventional X-ray tubes that produce X-ray photons with an energy distribution, that is, a spectrum. Consequently, the effective linear attenuation coefficient of an object, shown by the CT image, depends on the full energy spectrum, how it changes as it propagates through the object, and how it interacts with the detector. To emphasise contrasts in the final CT image, caused by density or compositional variations in the object investigated, the energy spectrum has to be chosen and shaped with filters in such a way that the differences in effective linear attenuation coefficient increase. However, it is empirically tedious to find optimal CT parameter settings for each individual imaging task, particularly for industrial CT, because of the wide range of object and defect combinations of interest.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A case of anomalous coronary artery origin: The role of computerised tomography

OBJECTIVE To illustrate the utility of CT coronary angiography in the assessment of patients with anomalous coronary arteries. METHODS A 65-year-old woman who presented with a clinical history of unstable angina was investigated with both computerised tomography and invasive coronary angiography. RESULTS Coronary angiography demonstrated aberrant coronary arteries all arising from separate ...

متن کامل

Subvalvular membrane on the left ventricular outflow tract: multidetector computerised tomography imaging.

In this report, we describe a patient with a subvalvular membrane on the left ventricular outflow tract. Discrete subvalvular membrane is a cause of left ventricular outflow tract narrowing. Multidetector computerised tomography can demonstrate the anatomical three-dimensional view of this region and guide for surgery.

متن کامل

Metastatic Adenocarcinoma of Temporal Bone with Collet-Sicard Syndrome

Introduction: Metastatic tumors of the temporal bone are extremely rare. Collet-Sicard syndrome is an uncommon condition characterized by unilateral palsy of the lower four cranial nerves. The clinical features of temporal bone metastasis are nonspecific and mimic infections such as chronic otitis media and mastoiditis.   Case Report: This report describes a rare case of metastatic adenocarcino...

متن کامل

Anatomical Variations of the Paranasal Sinuses in Patients with Chronic Rhino Sinusitis Using Computerised Tomography Scan (CT) - A Review

Computerised tomography (CT) scan imaging techniques acts as a guide for functional endoscopic sinus surgery (FESS). It plays a vital role in the successful outcome of the treatment and management of the paranasal sinus variations. The frequent predisposing factors of chronic sinusitis are the anatomical variations of the paranasal sinus and nasal region. Computed tomography (CT) scan plays a f...

متن کامل

Computerised Tomography Appearances of Partial Lipodystrophy Syndrome in Association with Membranoproliferative Glomerulonephritis Type 2

Partial lipodystrophy is a disease in which body fat is lost in an unusual distribution, with patients often having a typically gaunt facial appearance. The disease is sometimes seen in association with mesangiocapillary glomerulonephritis type 2. We describe the computerised tomography features in such a patient and demonstrate the unusual fatty distribution that may occur. To our knowledge th...

متن کامل

Is computerised tomography better than fibreoptic gastroscopy for early detection of gastric varices?

INTRODUCTION Video endoscopic diagnosis of gastric varices is particularly limited, owing to the deep submucosal or subserosal location of the varices and the normal appearance of the overlying mucosa. AIM We present and emphasise the value of computerised tomography (CT) examination in the early detection of gastric varices (GVs). MATERIAL AND METHODS In this retrospective study, a total o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of X-ray science and technology

دوره 8 3  شماره 

صفحات  -

تاریخ انتشار 1998