An automated, web-enabled and searchable database system for archiving electrogram and related data from implantable cardioverter defibrillators.
نویسندگان
چکیده
The advent of implantable cardioverter defibrillators (ICDs) has resulted in significant reductions in mortality in patients at high risk for sudden cardiac death. Extensive related basic research and clinical investigation continue. ICDs typically record intracardiac electrograms and inter-beat intervals along with device settings during episodes of device delivery of therapy. Researchers wishing to study these data further have until now been limited to viewing paper plots. In support of multi-center clinical studies of patients with ICDs, we have developed a web based searchable ICD data archiving system, which allows users to use a web browser to upload ICD data from diskettes to a server where the data are automatically processed and archived. Users can view and download the archived ICD data directly via the web. The entire system is built from open source software. At present more than 500 patient ICD data sets have been uploaded to and archived in the system. This project will be of value not only to those who wish to conduct research using ICD data, but also to clinicians who need to archive and review ICD data collected from their patients.
منابع مشابه
A case of inappropriate implantable cardioverter defibrillator therapy induced by T-wave oversensing due to hyperkalemia.
There have been reports of hyperkalemia-induced T-wave oversensing in patients with implantable cardioverter defibrillators (ICDs). However, a comparison of T-wave amplitudes and morphologies between the surface 12-lead electrocardiogram (ECG) and ICD electrogram has not been reported. We present the case of a 70-year-old man who received inappropriate ICD shocks due to hyperkalemia-induced T-w...
متن کاملAutomated vulnerability testing identifies patients with inadequate defibrillation safety margin.
BACKGROUND Implantable cardioverter-defibrillator system efficacy is tested at implant by induction of ventricular fibrillation (VF). Defibrillation safety margin can be assessed without VF induction using upper limit of vulnerability methods, but these methods have required manual determination of T-wave timing. METHODS AND RESULTS To test the feasibility of an inductionless system of implan...
متن کاملPerformance of Lead Integrity Alert to assist in the clinical diagnosis of implantable cardioverter defibrillator lead failures: analysis of different implantable cardioverter defibrillator leads.
BACKGROUND The Lead Integrity Alert (LIA) was developed for Medtronic implantable cardioverter defibrillators to reduce inappropriate shocks for rapid oversensing caused by conductor fractures and reported for Medtronic Fidelis conductor fractures. The goal of this study was to compare the performance of LIA with conventional impedance monitoring for identifying lead system events (LSEs) and le...
متن کاملMicropower Analogue Building Blocks for Template Matching in Implantable Devices
The design of analogue low power VLSI building block is very important for implantable devices, like cochlear implants and implantable cardioverter deebril-lators(ICD). In this paper we describe the micropower analogue building blocks for implementing the template matcher used for intracardiac electrogram (ICEG) clas-siication and data compression in an ICD. These blocks were fabricated using O...
متن کاملTHE EFFECT OF NURSE-PEER-LED SUPPORT INTERVENTION ON QUALITY OF LIFE IN PATIENTS WITH AN IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR: A RANDOMIZED CLINICAL TRIAL
Background & Aims: Nowadays, the quality of life and how coping and treatment of patients with an implantable cardiac defibrillator has led to concern and attempts to reduce or eliminate the problems of these patients in the people who provide health care services. This study aimed to determine the effect of nurse-peer-led support intervention on quality of life in patients with an implantable ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Computers in cardiology
دوره 29 شماره
صفحات -
تاریخ انتشار 2002