Application of unfolding technique to HPGe detector using response functions calculated with the EGS4 Monte Carlo code.

نویسندگان

  • Kook Jin Chun
  • Suck Ho Hah
  • Hyun Moon Kim
  • Gwang Ho Yoo
چکیده

The EGS4 Monte Carlo simulation technique was used to obtain the energy spectra of photons arriving at a detector from the pulse height distributions measured by the same detector. First, the measured pulse height distribution for incident photons from several radiation sources such as 60Co, 137Cs, 152Eu and 207Bi with a collimator are compared with those calculated using the EGS4 code to investigate the feasibility of the simulation. The comparison showed good agreement of 98.7% for 60Co, 92.5% for 207Bi on the total counts. Second, the pulse height distributions were measured in the open space and then unfolded. The measurement of the distributions was done with changing the source to detector distance (SDD) from 10 cm to 100 cm for 60Co and 137Cs respectively. In the unfolding process, response functions of a high purity Ge (HPGe) detector were calculated using the EGS4 code. The calculated pulse height distributions were then normalized to the measured ones at the peaks of the incident photon energies. The ratio of the sum of counts of the main peaks to the total count in the unfolded spectra for 60Co varied from 5.4 to 5.7 times greater than those in the measured pulse height distributions, while from 2.5 to 2.9 times for 137Cs. Electron contribution to the unfolded spectra for 137Cs decreased as the source to detector distance increased, becoming negligible above 50 cm. The pulse height distributions at the center of the reference plane at 100 cm from the 60Co and 137Cs dummy sources located inside each irradiator were also measured and unfolded to obtain the real pulse height distribution. In the unfolded spectra, the photons scattered from the surrounding materials were reduced to approximately one fourth of those measured in the open space due to the small size of apertures of the irradiators. The ratio of the sum of counts for the main peaks to the total count was larger than those in the measured pulse height distributions by the factor of 5.0 for 60Co and 3.4 for 137Cs. The uncertainties estimated in the unfolding processes were around 0.1% for 60Co and 0.07% for 137Cs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Unfolding X-ray spectrum in the diagnostic range using the Monte Carlo Code MCNP5

Introduction: Unfolding X-ray spectrum is a powerful tool for quality control of X-ray tubes. Generally, the acquisition of the X-ray spectrum in diagnostic radiology departments is complicated and difficult due to high photon flux. Measurement of x ray spectra using radiation detectors could not be performed accurately, because of the pulse pile up. Therefore, indirect methods...

متن کامل

Application of the Tikhonov Unfolding Method for Reconstruction of Primary X-Ray Spectra from X-Ray Equipments

Quality Control (QC) parameters for an X-ray tube depend strongly on the accurate assessment of the primary spectrum. In previous works, a methodology to assess primary spectrum using a Compton spectrometry technique has been analyzed. This methodology consists in the use of a Monte Carlo (MC) model, by means of the MCNP5 code, to reproduce the physical phenomena involving the interaction of ph...

متن کامل

Determination of virtual point for HPGe detector at various gamma rays energies by simulation and experimental methods

High Purity Germanium detectors (HPGe) are subdivisions of semiconductor detectors which are widely used in nuclear technology from space industry to nuclear medicine, due to their high resolution, low dead time, unlimited size and compatibility with a variety of environments. The( absolute and intrinsic) efficiency of the HPGe detector, which depends on the geometry of the source-detector syst...

متن کامل

Comparison of measured and Monte Carlo calculated dose distributions from “circular collimators” for radiosurgical beams

Background: Stereotactic radiosurgery is an important clinical tool for the treatment of small lesions in the brain, including benign conditions, malignant and localized metastatic tumors. A dosimetry study was performed for Elekta ‘Synergy S ’ as a dedicated Stereotactic radiosurgery unit, capable of generating circular radiation fields with diameters of 1-5 cm at isocentre using the BEAM/EGS4...

متن کامل

Experimental and Monte Carlo studies on the response of CR-39 detectors to Am-Be neutron spectrum

Background: The Poly-Allyl Diglycol Carbonate (PADC) detector is of particular interest for development of a fast neutron dosimeter. Fast neutrons interact with the constituents of the CR-39 detector and produce H, C and O recoils, as well as (n, α) reaction. These neutron- induced charged particles contribute towards the response of CR-39 detectors. Material and Methods: Electrochemical...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of radiation research

دوره 47 1  شماره 

صفحات  -

تاریخ انتشار 2006