Validation of roche COBAS Amplicor assay for detection of Chlamydia trachomatis in rectal and pharyngeal specimens by an omp1 PCR assay.

نویسندگان

  • N A Lister
  • S N Tabrizi
  • C K Fairley
  • S Garland
چکیده

Screening guidelines for men who have sex with men (MSM) recommend testing of extragenital sites (pharyngeal and rectal) for gonorrhoea and chlamydia. Testing of specimens from these sites is not validated by most commercial nucleic amplification tests, such as the COBAS Amplicor assay. To investigate the utility of the COBAS Amplicor assay for detection of Chlamydia trachomatis in extragenital specimens, this study developed and evaluated confirmatory tests using the omp1 gene as an alternative target for amplification by PCR. Of anal and throat swabs collected from men in male-only saunas, 52 swabs that tested C. trachomatis positive by COBAS Amplicor and 30 swabs that tested as negative were included for confirmatory omp1 PCR testing. A total of 49 (94%) COBAS Amplicor-positive samples were confirmed by the omp1 PCR. A substantial proportion of specimens were confirmed by using a nested omp1 PCR (27%). Not confirmed by any omp1 PCR were three anal swabs (6%). It is most probable that these samples contained lower bacterial levels that were near or below the detection level of the omp1 PCR assays. The findings of this study support the confident reporting of C. trachomatis detected by COBAS Amplicor in extragenital specimens and support the utility of this assay as a screening test for MSM.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of Chlamydia trachomatis prevalence in an asymptomatic screening population: performances of the LCx and COBAS Amplicor tests with urine specimens.

This study determined the performances of the LCx (Abbott) and COBAS Amplicor (Roche) tests with urine specimens for the detection of Chlamydia trachomatis in an asymptomatic screening population. Randomly selected women and men (age range, 15 to 40 years) registered in 20 general practices in Amsterdam, The Netherlands, were invited to participate in this study. Urine specimens (n = 2, 906; 1,...

متن کامل

Detection of Chlamydia trachomatis in genital swabs: comparison of commercial and in house amplification methods with culture.

AIMS To evaluate the sensitivity of the Roche Cobas, Roche Amplicor plate kit, ligase chain reaction (LCR), and an in house polymerase chain reaction (PCR) by titration of purified elementary bodies (EB) and also to test 245 urethral and endocervical specimens for Chlamydia trachomatis by the four assays as well as conventional culture. STUDY DESIGN EB titrations were run in duplicate in each...

متن کامل

Comparison between the LCx Probe system and the COBAS AMPLICOR system for detection of Chlamydia trachomatis and Neisseria gonorrhoeae infections in patients attending a clinic for treatment of sexually transmitted diseases in Amsterdam, The Netherlands.

Two assays for the detection of Chlamydia trachomatis and Neisseria gonorrhoeae were compared: the LCx Probe system (the LCx system; Abbott Diagnostic Laboratories, North Chicago, Ill.) and the COBAS AMPLICOR C. trachomatis/N. gonorrhoeae system (the COBAS AMPLICOR system; Roche Diagnostic Systems, Branchburg, N.J.). Endocervical swab specimens, male urethral swab specimens, and female and male...

متن کامل

An assessment of the Roche Amplicor Chlamydia trachomatis/Neisseria gonorrhoeae multiplex PCR assay in routine diagnostic use on a variety of specimen types.

The Roche Cobas Amplicor Chlamydia trachomatis/Neisseria gonorrhoeae polymerase chain reaction (PCR) assay can simultaneously detect both C. trachomatis and N. gonorrhoeae, and has been cleared by United States Food and Drug Administration (FDA) for the testing of endocervical and urethral swabs and urine specimens. The Amplicor N. gonorrhoeae PCR target sequence is known to be present in some ...

متن کامل

Preparation and validation of PCR-generated positive controls for diagnostic dot blotting.

References 1. Loeffelholz MJ, Lewinski CA, Silver SR, Purohit AP, Herman SA, Buonagurio DA, Dragon EA. Detection of Chlamydia trachomatis in endocervical specimens by polymerase chain reaction. J Clin Microbiol 1992;30:2847–51. 2. Bass CA, Jungkind DL, Silverman NS, Bondi JM. Clinical evaluation of a new polymerase chain reaction assay for detection of Chlamydia trachomatis in endocervical spec...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 42 1  شماره 

صفحات  -

تاریخ انتشار 2004