Positron-emission tomography imaging of the angiotensin II subtype 1 receptor in swine renal artery stenosis.

نویسندگان

  • Jinsong Xia
  • Esen Seckin
  • Yan Xiang
  • Melin Vranesic
  • William B Mathews
  • Kelvin Hong
  • David A Bluemke
  • Lilach O Lerman
  • Zsolt Szabo
چکیده

The angiotensin II subtype 1 receptor (AT(1)R) has been linked to the development and progression of renovascular hypertension. In this study we applied a pig model of renovascular hypertension to investigate the AT(1)R in vivo with positron-emission tomography (PET) and in vitro with quantitative autoradiography. AT(1)R PET measurements were performed with the radioligand [(11)C]KR31173 in 11 control pigs and in 13 pigs with hemodynamically significant renal artery stenosis; 4 were treated with lisinopril for 2 weeks before PET imaging. The radioligand impulse response function was calculated by deconvolution analysis of the renal time-activity curves. Radioligand binding was quantified by the 80-minute retention of the impulse response function. Median values and interquartile ranges were used to illustrate group statistics. Radioligand retention was significantly increased (P=0.044) in hypoperfused kidneys of untreated (0.225; range: 0.150 to 0.373) and lisinopril-treated (0.237; range:0.224 to 0.272) animals compared with controls (0.142; range:0.096 to 0.156). Increased binding of [(11)C]KR31173 documented by PET in vivo was confirmed by in vitro autoradiography. Both in vivo and in vitro binding measurements showed that the effect of renal artery stenosis on the AT(1)R was not abolished by lisinopril treatment. These studies provide insight into kidney biology as the first in vivo/in vitro experimental evidence about AT(1)R regulation in response to reduced perfusion of the kidney. The findings support the concept of introducing AT(1)R PET as a diagnostic biomarker of renovascular disease.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intrarenal perfusion and angiotensin II levels regulate in vivo angiotensin II type 1 receptor imaging in the kidney.

Intrarenal Perfusion and Angiotensin II Levels Regulate In Vivo Angiotensin II Type 1 Receptor Imaging in the Kidney To the Editor: In the recent issue of Hypertension, Dr Szabo’s group used novel positron-emission tomographic (PET) [C]KR31173 imaging to study the regulation of intrarenal angiotensin II type 1 (AT1) receptor binding in a swine model of renal artery stenosis in vivo.1 In this st...

متن کامل

Systemic atherosclerotic plaque vulnerability in patients with Coronary Artery Disease with a single Whole Body [FDG]PET-CT scan

Objective(s): Cardiovascular disease is a leading cause of morbimortality with over half cardiovascular events occurring in the asymptomatic population by traditional risk stratification. This preliminary study aimed to evaluate systemic plaque vulnerability in patients with prior Coronary Artery Disease (CAD) with a single Whole Body [FDG] PET-CT scan in terms of plaq...

متن کامل

Renin-angiotensin system and unilateral ureteral obstruction

Unilateral ureteral obstruction (UUO) is a clinical scenario that leads to obstructive nephropathy. UUO alters the expression of many mediators in the ipsilateral kidney. Renin-angiotensin system (RAS) is involved in UUO. Angiotensin II (Ang II) and angiotensin 1-7 (Ang 1-7) as the main arms of RAS influence kidney function which may alter by UUO. Ang II via Ang II receptor subtypes I (AT1R) ...

متن کامل

Use of positron emission tomography to study AT1 receptor regulation in vivo.

Increased sodium intake and enhanced sodium sensitivity are implicated in the pathogenesis of hypertension and in the control of a major regulator of BP, the type 1 angiotensin receptor (AT(1) receptor). An in vivo technique to study changes of renal AT(1) receptors by dietary sodium was developed that uses positron emission tomography (PET). PET revealed that renal cortical AT(1) receptor bind...

متن کامل

The effect of fasting on Positron Emission Tomography (PET) imaging

As a nuclear approach, Positron Emission Tomography (PET) is a functional imaging technique which is based on the detection of gamma ray pairs emitted by a positron-emitting radionuclide. There are certain limitations to this technique such as normal tissue uptake. Therefore, it has been recommended that patients prepare before scanning. Fasting for a short while before PET imaging is an exampl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Hypertension

دوره 51 2  شماره 

صفحات  -

تاریخ انتشار 2008