Cardiac dyssynchrony analysis using circumferential versus longitudinal strain: implications for assessing cardiac resynchronization.
نویسندگان
چکیده
BACKGROUND QRS duration is commonly used to select heart failure patients for cardiac resynchronization therapy (CRT). However, not all patients respond to CRT, and recent data suggest that direct assessments of mechanical dyssynchrony may better predict chronic response. Echo-Doppler methods are being used increasingly, but these principally rely on longitudinal motion (epsilonll). It is unknown whether this analysis yields qualitative and/or quantitative results similar to those based on motion in the predominant muscle-fiber orientation (circumferential; epsiloncc). METHODS AND RESULTS Both epsilonll and epsiloncc strains were calculated throughout the left ventricle from 3D MR-tagged images for the full cardiac cycle in dogs with cardiac failure and a left bundle conduction delay. Dyssynchrony was assessed from both temporal and regional strain variance analysis. CRT implemented by either biventricular (BiV) or left ventricular-only (LV) pacing enhanced systolic function similarly and correlated with improved dyssynchrony based on epsiloncc-based metrics. In contrast, longitudinal-based analyses revealed significant resynchronization with BiV but not LV for the overall cycle and correlated poorly with global functional benefit. Furthermore, unlike circumferential analysis, epsilonll-based indexes indicated resynchronization in diastole but much less in systole and had a lower dynamic range and higher intrasubject variance. CONCLUSIONS Dyssynchrony assessed by longitudinal motion is less sensitive to dyssynchrony, follows different time courses than those from circumferential motion, and may manifest CRT benefit during specific cardiac phases depending on pacing mode. These results highlight potential limitations to epsilonll-based analyses and support further efforts to develop noninvasive synchrony measures based on circumferential deformation.
منابع مشابه
Strain dyssynchrony index determined by three-dimensional speckle area tracking can predict response to cardiac resynchronization therapy
BACKGROUND We have previously reported strain dyssynchrony index assessed by two-dimensional speckle tracking strain, and a marker of both dyssynchrony and residual myocardial contractility, can predict response to cardiac resynchronization therapy (CRT). A newly developed three-dimensional (3-D) speckle tracking system can quantify endocardial area change ratio (area strain), which coupled wit...
متن کاملAssessment of left ventricular dyssynchrony by speckle tracking strain imaging comparison between longitudinal, circumferential, and radial strain in cardiac resynchronization therapy.
OBJECTIVES The objective of this study was to assess the usefulness of each type of strain for left ventricular (LV) dyssynchrony assessment and its predictive value for a positive response after cardiac resynchronization therapy (CRT). Furthermore, changes in extent of LV dyssynchrony for each type of strain were evaluated during follow-up. BACKGROUND Different echocardiographic techniques h...
متن کاملDyssynchrony by speckle-tracking echocardiography and response to cardiac resynchronization therapy: results of the Speckle Tracking and Resynchronization (STAR) study
AIMS The Speckle Tracking and Resynchronization (STAR) study used a prospective multi-centre design to test the hypothesis that speckle-tracking echocardiography can predict response to cardiac resynchronization therapy (CRT). METHODS AND RESULTS We studied 132 consecutive CRT patients with class III and IV heart failure, ejection fraction (EF) < or =35%, and QRS > or =120 ms from three inter...
متن کاملPrinciple component analysis of myocardial strain to quantify left ventricular dyssynchrony
Background Cardiac resynchronization therapy (CRT) is effective for selected heart failure (HF) patients, but is associated with a 30-40% nonresponse rate. Identification of CRT responders may be improved with myocardial strain imaging. The circumferential uniformity ratio estimate (CURE ) measures mechanical dyssynchrony by Fourier series fitting of myocardial strains over space, but requires ...
متن کاملQuantitative assessment of left ventricular mechanical dyssynchrony using cine cardiovascular magnetic resonance imaging: Inter-study reproducibility
OBJECTIVES To determine the inter-study reproducibility of left ventricular (LV) mechanical dyssynchrony measures based on standard cardiovascular magnetic resonance (CMR) cine images. DESIGN Steady-state free precession (SSFP) LV short-axis stacks and three long-axes were acquired on the same day at three time points. Circumferential strain systolic dyssynchrony indexes (SDI), area-SDI as we...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 111 21 شماره
صفحات -
تاریخ انتشار 2005