Repositioning of glaucoma tubes into the pars plana for refractory malignant glaucoma: a case report
نویسندگان
چکیده
INTRODUCTION Malignant glaucoma occurs when the intraocular pressure elevates in the setting of a shallow anterior chamber and patent iridectomy. We describe a case in which malignant glaucoma that was refractory to conventional treatment and complete vitrectomy was successfully managed by rerouting the glaucoma tubes into the pars plana. CASE PRESENTATION A 47-year-old Latino man had a history of neovascular glaucoma and subsequent peripheral anterior synechiae. He was status post-two glaucoma drainage devices. He developed pupillary block. Laser iridotomy was performed without complications. He subsequently developed malignant glaucoma that was refractory to yttrium aluminum garnet capsulohyaloidotomy of the anterior hyaloid. He underwent pars plana vitrectomy with successful control of his intraocular pressure. After 2 weeks, the malignant glaucoma recurred. He underwent repositioning of the tubes into the pars plana with successful control of his intraocular pressure. CONCLUSION In rare cases of malignant glaucoma refractive to yttrium aluminum garnet hyaloidotomy and vitrectomy, placement of glaucoma drainage devices is a reasonable alternative.
منابع مشابه
Two cases of malignant glaucoma unresolved by pars plana vitrectomy
Malignant glaucoma, which is characterized by a shallow or flat anterior chamber with high intraocular pressure, can usually be resolved by pars plana vitrectomy with anterior hyaloidectomy. We describe two cases in which malignant glaucoma was refractory to conventional treatment and complete vitrectomy. Case one an 88-year-old woman with pseudoexfoliation glaucoma underwent trabeculotomy and ...
متن کاملEfficacy and safety of the pars plana clip in the Ahmed valve device inserted via the pars plana in patients with refractory glaucoma
PURPOSE To evaluate the efficacy and safety of the pars plana clip (PPC) in the Ahmed valve tube inserted via the pars plana in patients with secondary refractory glaucomas. METHODS Prospective and interventional case series that included 10 patients with secondary refractory glaucoma. The pars plana vitrectomy and the implant of the modified tube were performed during the same surgery. Contr...
متن کاملA case of 25 gauge vitrectomy for malignant glaucoma with microphthalmos
UNLABELLED We report the first case report of pars plana lensectomy (PPL) and pars plana vitrectomy using a 25 gauge vitrectomy system for microphthalmos. RESULTS A 45-year-old woman reported repeated pain in her left eye, despite the use of medications. Ultrasound biomicroscopy revealed a narrow angle and thickened sclera. The lens and the iris showed anterior displacement with a flattening ...
متن کاملEndoscopic Cyclophotocoagulation and Pars Plana Ablation (ECP-plus) to Treat Refractory Glaucoma.
PURPOSE To report clinical outcomes after pars plana endoscopic cyclophotocoagulation of the ciliary processes and pars plana (ECP-plus), a novel treatment for refractory glaucoma. DESIGN Retrospective, noncomparative interventional case series. MATERIALS AND METHODS SETTING multicenter tertiary referral academic and clinical practice. STUDY POPULATION fifty-three eyes of 53 consecutiv...
متن کاملPars plana vitrectomy for malignant glaucoma in nonglaucomatous and in filtered glaucomatous eyes
PURPOSE To assess the outcomes of pars plana vitrectomy for the treatment of malignant glaucoma in patients with and without previous filtration surgery. PATIENTS AND METHODS Data of 15 patients developing malignant glaucoma after trabeculectomy (60%) or following ophthalmic interventions other than filtration surgery (40%) were recorded retrospectively. Pars plana vitrectomy was performed in...
متن کامل