Accurate Optical Frequency Measurement and Synthesis
نویسنده
چکیده
In recent times a remarkable breakthrough has occurred in the field of optical frequency measurement and synthesis. For the first time it is now possible to generate arbitrary waveform light pulses, perform accurate optical frequency synthesis and accurately measure the frequency of optical frequency signals. These long dreamed of possibilities have been delivered because of the existence of two innovative technologies: ultrafast pulsed lasers that generate pulses only a few optical cycles in duration, and specially tailored optical fibre that can broaden the output spectrum of these light pulses across the entire optical spectrum. In a seemingly improbably feat, this combination of the extremely fast and extremely broad has proven to enable reliable measurements with a higher precision than any other technique. This article outlines the mechanisms inherent to the operation of the pulsed laser, as well as the tailored optical fibre, and then presents the techniques that enable the promised frequency synthesis and measurement.
منابع مشابه
A phase-locked frequency divide-by-3 optical parametric oscillator
Accurate phase-locked 3:1 division of an optical frequency was achieved, by using a continuous-wave (cw) doubly resonant optical parametric oscillator. A fractional frequency stability of 2×10-17 of the division process has been achieved for 100 s integration time. The technique developed in this work can be generalized to the accurate phase and frequency control of any cw optical parametric os...
متن کاملIncreasing the Accuracy of Blood Hematocrit Measurement by Triplicate Wavelength Photoplethysmography Method
Background and objectives: The importance of continuous monitoring and rapid and accurate informing of changes in blood components (e.g., percentage of hematocrit [HCT]), especially in acute conditions, has motivated researchers to use non-invasive measurement methods. Therefore, this study aimed to evaluate the association between blood HCT and photoplethysmographic signal and the possibility ...
متن کاملDesigning and developing an in-house CCD based optical CT scanner for gel dosimetry
Introduction: Measurement of the complex 3D radiation dose distribution created with advanced radiotherapy techniques such as IMRT and SRS became very important. Polymer gel dosimetry (PGD) is proposed method to recording this dose distribution. MRI, X-ray CT, ultrasound, spectrophotometry and optical CT scanners can be used for readout of Polymer gel dosimeters. Although MRI i...
متن کاملPerformance Analysis Of Mono-bit Digital Instantaneous Frequency Measurement (Difm) Device
Instantaneous Frequency Measurement (IFM) devices are the essential parts of anyESM, ELINT, and RWR receiver. Analog IFMs have been used for several decades. However, thesedevices are bulky, complex and expensive. Nowadays, there is a great interest in developing a wideband, high dynamic range, and accurate Digital IFMs. One Digital IFM that has suitably reached allthese requirements is mono-bi...
متن کاملAccuracy comparison of absolute optical frequency measurement between harmonic-generation synthesis and a frequency-division femtosecond comb
Using an iodine-stabilized He-Ne laser as a transfer oscillator, we compare absolute measurements of the optical frequency from a traditional frequency synthesis chain based on harmonic generation and from the frequency division technique of an ultrawide bandwidth femtosecond frequency comb. The agreement between these two measurements, both linked to the Cs standard, is 220+/-770 Hz, yielding ...
متن کامل