Factors influencing flip angle mapping in MRI: RF pulse shape, slice-select gradients, off-resonance excitation, and B0 inhomogeneities.

نویسندگان

  • Jinghua Wang
  • Weihua Mao
  • Maolin Qiu
  • Michael B Smith
  • R Todd Constable
چکیده

To understand the various effects that influence actual flip angles, and correct for these effects, it is important to precisely quantify the MRI parameters (such as T1, T2, and perfusion). In this paper actual flip angle maps are calculated using a conventional gradient-echo (GRE) sequence with different radiofrequency (RF) pulse shapes (Gaussian, sinc, and truncated-sinc), slice-selection gradients, off-resonance excitations, and B0 field inhomogeneities. The experimental results demonstrate that RF pulse shapes significantly affect the flip angle distribution and calibration factors. Off-resonance RF excitations, B0 nonuniformities, and slice-selection gradients can lead to degradations in the signal intensities of the images used to map the flip angle, and potentially introduce a bias and increased variance in the measured flip angles.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance of Three Transmitter Calibration Methods for Hyperpolarized Gas MRI in the Presence of B0 and B1 Inhomogeneity

Introduction: Due to the non-equilibrium nature of hyperpolarized magnetization, methods suitable for calibrating the transmitter voltage (or, equivalently, mapping the transmit B1 field) are inherently different than those for proton MRI. Mugler et al presented a low-flip-angle, phase-based method for calibrating the transmitter voltage [1,2], which was extended by Santoro et al to provide low...

متن کامل

Multiband RF Excitation for Accelerating Magnetic Resonance Imaging in the Presence of Metal

Target Audience: Researchers interested in MR methods for imaging near metallic implants. Purpose: Recent 3D multispectral imaging (MSI) techniques have dramatically reduced off-resonance artifacts near metal by acquiring multiple 3D-FSE acquisitions at different RF offsets and summing over all RF bins. In-plane distortion, however, remains a problem in areas with extreme local B0 gradients due...

متن کامل

Correcting for Strong Eddy Current Induced B0 Modulation Enables Two-Spoke RF Pulse Design with Parallel Transmission: Demonstration at 9.4T in the Human Brain

Successful implementation of homogeneous slice-selective RF excitation in the human brain at 9.4T using 16-channel parallel transmission (pTX) is demonstrated. A novel three-step pulse design method incorporating fast real-time measurement of eddy current induced B0 variations as well as correction of resulting phase errors during excitation is described. To demonstrate the utility of the propo...

متن کامل

Optimization of 3D EPI technique for radio frequency (B1) field mapping at 3T

Introduction Spatial inhomogeneities in the radio-frequency (RF) field (B1) increase with field strength as the RF wavelength approaches the dimensions of the human head. B1 inhomogeneities pose various problems such as spurious signal and contrast changes in MRI, leading to bias in quantitative imaging and difficulties in tissue segmentation. Here, we optimize the 3D EPI B1 mapping method intr...

متن کامل

Rapid RF Field Mapping Using a Slice-Selective Pre-conditioning RF Pulse

Introduction: In MRI, radiofrequency (RF) field (B1) inhomogeneity can produce flip angle variations, which can ultimately lead to signal intensity variations and quantitative measurement errors. By independently calibrating the local spatial variation of B1, the RFrelated signal variations can be corrected. The most widely used B1 mapping method is the double angle method (DAM) [1], which uses...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 56 2  شماره 

صفحات  -

تاریخ انتشار 2006