Cerebral blood flow response pattern during balloon test occlusion of the internal carotid artery.

نویسندگان

  • J P Witt
  • H Yonas
  • C Jungreis
چکیده

PURPOSE To evaluate the risk of temporary or permanent internal carotid artery occlusion. METHODS In 156 patients intraarterial balloon test occlusion in combination with a stable xenon-enhanced CT cerebral blood flow study was performed before radiologic or surgical treatment. All 156 patients passed the clinical balloon test occlusion and underwent a xenon study in combination with a second balloon test. Quantitative flow data were analyzed for absolute changes as well as changes in symmetry. RESULTS Fourteen patients exhibited reduced flow values between 20 and 30 mL/100 g per minute, an absolute decrease in flow, and significant asymmetry in the middle cerebral artery territory during balloon test occlusion. These patients would be considered at high risk for cerebral infarction if internal carotid artery occlusion were to be performed. With one exception they belonged to a group (class I) of 61 patients who showed bilateral or ipsilateral flow decrease and significant asymmetry with lower flow on the side of occlusion. The other 95 patients, who showed a variety of cerebral blood flow response patterns including ipsilateral or bilateral flow increase, were at moderate (class II) or low (class III) stroke risk. In contrast to these findings, exclusively qualitative flow analysis failed to identify the patients at high risk: a threshold with an asymmetry index of 10% revealed only 16% specificity whereas an asymmetry index of 45% showed only 61% sensitivity for detection of low flow areas (< 30 mL/100 g per minute). CONCLUSION For achieving a minimal hemodynamic related-stroke rate associated with permanent clinical internal carotid artery occlusion we suggest integration of a thorough analysis of quantitative cerebral blood flow data before and during balloon test occlusion.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

[15O]H2O positron emission tomography determination of cerebral blood flow during balloon test occlusion of the internal carotid artery.

PURPOSE To determine the utility of [15O]H2O positron emission tomography (PET) for the quantitative determination of cerebral blood flow in patients undergoing balloon test occlusion of the internal carotid artery. METHODS Twenty-two [15O]H2O PET cerebral blood flow studies were completed on 20 patients for whom temporary or permanent occlusion of the internal carotid artery was being consid...

متن کامل

A Lumped Parameter Method to Calculate the Effect of Internal Carotid Artery Occlusion on Anterior Cerebral Artery Pressure Waveform

Background and Objective: Numerical modeling of biological structures would be very helpful tool to analyze hundreds of human body phenomena and also diseases diagnosis. One physiologic phenomenon is blood circulatory system and heart hemodynamic performance that can be simulated by utilizing lumped method. In this study, we can predict hemodynamic behavior of one artery of circulatory system (...

متن کامل

Continuous time estimation as a behavioural index of human cerebral ischaemia during temporary occlusion of the internal carotid artery.

OBJECTIVE To determine whether a continuous time estimation task during test occlusions of either internal carotid artery would increase the ability to detect the earliest signs of cerebral ischaemia in the anterior circulation. METHODS Four patients were involved in real time measurement of their timing accuracy before, during, and after each test occlusion. While under each test condition, ...

متن کامل

Temporary balloon occlusion of the carotid artery combined with brain blood flow imaging as a test to predict tolerance prior to permanent carotid sacrifice.

PURPOSE To describe the technique of using SPECT brain blood flow imaging to identify patients at risk for having strokes after balloon or surgical ligation of an internal carotid artery. PATIENTS AND METHODS 29 patients underwent temporary balloon occlusion of the internal carotid artery and blood flow imaging studies were obtained prior to sacrifice of the vessel; 11 internal carotid arteri...

متن کامل

Monitoring cerebral oxygenation during balloon occlusion with multichannel NIRS

We report on oxygenation changes noninvasively recorded by multichannel continuous-wave near infrared spectroscopy (CW-NIRS) during endovascular neuroradiologic interventions requiring temporary balloon occlusion of arteries supplying the cerebral circulation. Digital subtraction angiography (DSA) provides reference data on the site, timing, and effectiveness of the flow stagnation as well as o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 15 5  شماره 

صفحات  -

تاریخ انتشار 1994