Biomechanical study of rod stress after pedicle subtraction osteotomy versus anterior column reconstruction: A finite element study
نویسندگان
چکیده
BACKGROUND In an effort to minimize rod fractures and nonunion in pedicle subtraction osteotomy (PSO) constructs, surgeons have adopted multirod constructs and interbody cages. Anterior column realignment (ACR) with posterior column osteotomies is a minimally invasive alternative to PSO in sagittal balance correction, however, there is a paucity of evidence with respect to rod survival. METHODS Three-dimensional (3D) finite-element-model of a T12-sacrum spine segment was used to compare a 25° PSO at L3 and an ACR with a posterior column osteotomy and 30° hyperlordotic interbody cage at L3-4. The amount of overall T12-S1 lordosis correction was the same for each condition. Each simulation included cobalt chromium alloy primary rods with: (1) PSO; (2) PSO with an interbody cage (IB) at L2-3 (PSO+IB); (3) PSO with accessory (A) rods and IB at L2-3 (PSO+IB+A); (4) PSO with satellite (S) rods and IB at L2-3 (PSO+IB+2S); (5) ACR; 6) ACR with satellite rods (ACR + 2S). A 400 N follower preload was simulated for each condition. RESULTS PSO condition had the largest rod stress of 286 MPa in flexion. Adding interbody support reduced the rod stress by 15%. The 4-rod constructs further reduced rod stress, with the satellite rod condition facilitating the largest reduction. The rod stress in the ACR+2S was equivalent to the PSO+2S, with 50% reduction in rod stress. CONCLUSION The rod stress with an ACR was comparable to a PSO coupled with interbody support. These results suggest an ACR is a viable MIS alternative to a PSO without the need for a large posterior osteotomy.
منابع مشابه
Use of Supplemental Short Pre-Contoured Accessory Rods and Cobalt Chrome Alloy Posterior Rods Reduces Primary Rod Strain and Range of Motion Across the Pedicle Subtraction Osteotomy Level
and accessory rods at PSO level. Testing evaluated (1) accessory Study Design. In vitro cadaveric biomechanical study. Objective. To assess effects of 4-rod reconstruction, rod material, and anterior column support on motion and surface rod strain in a pedicle subtraction osteotomy model. Summary of Background Data. Pedicle subtraction osteotomy (PSO) can correct significant sagittal deformity ...
متن کاملPedicle Subtraction Osteotomy in a 5-Year-Old Child with Congenital Kyphosis
Vertebral anomalies may also distort the normal regional or global spinal alignment and necessitate some therapeutic interventions. Hemiepiphysiodesis is a traditional procedure usually described for these young patients but in more severe cases some type of osteotomy seems to be necessary. In this technical note, we describe a 5-year-old boy with failed previous hemiepiphysiodesis surgery, who...
متن کاملThe transmission of stress to grafted bone inside a titanium mesh cage used in anterior column reconstruction after total spondylectomy: a finite-element analysis.
STUDY DESIGN A finite-element study of posterior alone or anterior/posterior combined instrumentation following total spondylectomy and replacement with a titanium mesh cage used as an anterior strut. OBJECTIVES To compare the effect of posterior instrumentation versus anterior/posterior instrumentation on transmission of the stress to grafted bone inside a titanium mesh cage following total ...
متن کاملAnalysis of instrumentation failures after three column osteotomies of the spine
BACKGROUND Correction of fixed spinal imbalance in a sagittal and/or coronal plane frequently needs a tricolumnar wedge resection when the deformity is rigid. Complications associated with deformity correction surgery are pseudoarthrosis and implant failure located along the construct. The purposes of this study were to assess comparative rates of pseudoarthrosis (implant failure) at weaker poi...
متن کاملBiomechanical analysis of revision strategies for rod fracture in pedicle subtraction osteotomy.
BACKGROUND Pseudoarthrosis after pedicle subtraction osteotomy (PSO) can require revision surgery due to posterior rod failure, and the stiffness of these revision constructs has not been quantified. OBJECTIVE To compare the multidirectional bending stiffness of 7 revision strategies following rod failure. METHODS Seven fresh-frozen human spines (T11-pelvis) were tested as follows: (1) post...
متن کامل