Prospective evaluation of the correlation between torso height and aortic anatomy in respect of a fluoroscopy free aortic balloon occlusion system.
نویسندگان
چکیده
BACKGROUND To report the lengths of key torso vascular and to develop regression models that will predict these lengths, based on an external measure of torso height (EMTH, sternum to pubis) in the development of a fluoroscopy-free balloon occlusion system for hemorrhage control. METHODS We conducted a prospective, observational study at a Combat Support Hospital in Southern Afghanistan using adult male patients undergoing computed tomography (CT). EMTH was recorded using a tape measure and intra-arterial distance was derived from CT imaging. Regression models to predict distance from the common femoral artery (CFA) into the middle of aortic zone I (left subclavian artery to celiac trunk) and zone III (infrarenal aorta) were developed from a random 20% of the cohort and validated by the remaining 80%. RESULTS Overall, 177 male patients were included with a median (interquartile range [IQR]) age of 23 (8) years. The median (IQR) lengths of aortic zone I and III were 222 (24), 31 (9), and 92 (15) mm. The mid-zone distance from the left and right CFA to zone I were 423 (27) and 418 (29) and for zone III 232 (21) and 228 (22). Linear regression models demonstrated an accuracy between 99.3% to 100% at predicting the insertion distance required to place a catheter within the middle of each aortic zone. CONCLUSION This study demonstrates the use of morphometric analysis in the development of a fluoroscopy-free balloon occlusion system for torso hemorrhage control. Further study in a larger population of mixed gender is required to further validate insertion models.
منابع مشابه
The Evaluation of Survival in Patients Who Need Intra Aortic Balloon Pump (IABP) after Cardiac Surgery
Introduction: Insome cases, assist devices are required to ensure an adequate cardiac output after cardiac surgery. Intra-aortic balloon pump (IABP) is the most commonly used cardiac assist device, which provides first-line support for patients with heart failure. The aim of this study was to determine factors affecting the mortality rate of patients receiving IABP. Materials & Methods: In thi...
متن کاملBALLOON ANGIOPLASTY IN NATIVE AORTIC COARCTATION: RESULT S IN SHIRAZ AND REVIEW OF ARTICLES
Balloon angioplasty for aortic coarctation was introduced in 1979 for the fust time.1 This procedure soon became the choice treatment for restenosis of operated coarctation,2-5 but remains controversial for native (unoperated) coarctation. However, it seems to be rapidly becoming the intervention of choice for relief of unoperated coarctation as well. In this study, we evaluate the outcome ...
متن کاملFluoroscopy-free Resuscitative Endovascular Balloon Occlusion of the Aorta (REBOA) for controlling life threatening postpartum hemorrhage
BACKGROUND Severe postpartum hemorrhage occurs in 1/1000 women giving birth. This condition is often dramatic and may be life threatening. Resuscitative Endovascular Balloon Occlusion of the Aorta (REBOA) has in recent years been introduced as a novel treatment for hemorrhagic shock. We present a series of fluoroscopy-free REBOA for controlling life threatening postpartum hemorrhage. METHODS ...
متن کاملمقایسه نتایج درمانی بالون والوپلاستی و والوتومی جراحی در بیماران مبتلا به تنگی مادرزادی دریچه آئورت در پیگیری 6 ساله در بخش کودکان بیمارستان قلب شهید رجایی تهران
Background: Balloon valvuloplasty is a relatively new technique for relief of obstruction of aortic valve. The primary results of this procedure are similar to surgical valvotomy with fewer complications and mortality. Materials and methods: One hundred fifty-five patients with congenital aortic stenosis were enrolled in this study over a period of 6 years (1991-1997). Participants were all un...
متن کاملA novel fluoroscopy-free, resuscitative endovascular aortic balloon occlusion system in a model of hemorrhagic shock.
BACKGROUND Resuscitative endovascular balloon occlusion of the aorta (REBOA) is a potentially lifesaving maneuver in the setting of hemorrhagic shock. However, emergent use of REBOA is limited by existing technology, which requires large sheath arterial access and fluoroscopy-guided balloon positioning. The objectives of this study were to describe a new, fluoroscopy-free REBOA system and to co...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Surgery
دوره 155 6 شماره
صفحات -
تاریخ انتشار 2014