Orbital lymphoproliferative disorders (OLPDs): value of MR imaging for differentiating orbital lymphoma from benign OPLDs.
نویسندگان
چکیده
BACKGROUND AND PURPOSE Accurate discrimination of orbital lymphoma from benign orbital lymphoproliferative disorders is crucial for treatment planning. We evaluated MR imaging including DWI and contrast-enhanced MR imaging for differentiating orbital lymphoma from benign orbital lymphoproliferative disorders. MATERIALS AND METHODS Forty-seven histopathologically proved orbital lymphoproliferative disorders (29 orbital lymphomas and 18 benign orbital lymphoproliferative disorders) were evaluated. Two board-certified radiologists reviewed visual features on T1-weighted, fat-suppressed T2-weighted, diffusion-weighted, and contrast-enhanced MR images. For quantitative evaluation, ADC and contrast-enhancement ratio of all lesions were measured and optimal cutoff thresholds and areas under curves for differentiating orbital lymphoma from benign orbital lymphoproliferative disorders were determined using receiver operative characteristic analysis; corresponding sensitivities and specificities were calculated. RESULTS Multivariate logistic regression analysis showed that ill-defined tumor margin (P = .003) had a significant association with orbital lymphoma whereas the "flow void sign" (P = .005) and radiologic evidence of sinusitis (P = .0002) were associated with benign orbital lymphoproliferative disorders. The mean ADC and contrast-enhancement ratio of orbital lymphomas were significantly lower than those of benign orbital lymphoproliferative disorders (P < .01). An ADC of less than 0.612 × 10(-3) mm(2)/s and a contrast-enhancement ratio of less than 1.88 yielded areas under curves of 0.980 and 0.770, sensitivity of 94.1% and 95.5%, and specificities of 93.3% and 80.0% for predicting orbital lymphoma, respectively. CONCLUSIONS Some characteristic MR imaging features and quantitative DWI and contrast-enhanced MR imaging are useful in further improving the accuracy of MR imaging for differentiation of orbital lymphoma from benign orbital lymphoproliferative disorders.
منابع مشابه
Benign and malignant orbital lymphoproliferative disorders: Differentiating using multiparametric MRI at 3.0T.
PURPOSE To determine the optimal combination of parameters derived from 3T multiparametric (conventional magnetic resonance imaging [MRI], diffusion-weighted [DW] and dynamic contrast-enhanced [DCE]) MRI for differentiating malignant from benign orbital lymphoproliferative disorders (OLPDs). MATERIALS AND METHODS Forty patients with OLPDs (18 benign and 22 malignant) underwent conventional 3....
متن کاملValue of MR imaging in differentiation between solitary fibrous tumor and schwannoma in the orbit.
BACKGROUND AND PURPOSE Orbital SFT is a rare tumor, often misdiagnosed as orbital schwannoma preoperatively but with different prognosis and treatment. Our aim was to evaluate MR imaging features that might distinguish orbital SFT from schwannoma. MATERIALS AND METHODS MR imaging including DCE scanning was performed in 9 patients with SFT and 22 patients with schwannoma in the orbit confirmed...
متن کاملComparison of the Results of Fine Needle Aspiration Biopsy Specimens and Permanent Histopathologic Preparation in Orbital Mass Lesions
Background and Objectives: We aimed at evaluating the efficacy of fine needle aspiration biopsy (FNA) in comparison with histopathology and demonstrating whether cytological study could be a proper diagnostic tool in orbital mass lesions. Materials and Methods: In a cross sectional study during 36 months, patients referred to our ophthalmologic center affiliated to Tehran University of Medical...
متن کاملClinical Aspects of IgG4-Related Orbital Inflammation in a Case Series of Ocular Adnexal Lymphoproliferative Disorders
The most frequent ocular adnexal tumors and simulating lesions are lymphoproliferative disorders (LPDs), including malignant lymphomas and orbital inflammation with lymphoid hyperplasia or infiltration. IgG4-related orbital inflammation (IgG4-ROI) often involves lacrimal glands and other orbital tissues and is an important differential diagnosis. The present study evaluated clinical aspects of ...
متن کاملFine Needle Aspiration Cytology of Intraocular, Orbital and Eyelid Lesions
Background: Fine-Needle Aspiration Cytology (FNAC) is used for diagnosis of intraocular, orbital and eyelid lesions. In this study we evaluated the outcome and the accuracy of using this technique in diagnosis of benign or malignant behavior of lesions. Methods: FNAC was performed on 26 specimens obtained from 25 patients with intraocular, orbital and eyelid tumors and the results were compared...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 35 10 شماره
صفحات -
تاریخ انتشار 2014