Immersion A-scan compared with partial coherence interferometry: outcomes analysis.
نویسندگان
چکیده
PURPOSE To compare 2 methods of axial length measurement, immersion ultrasonography and partial coherence interferometry, and to elucidate surgical outcomes based on immersion measurements. SETTING Oregon Eye Institute, Eugene, Oregon, USA. METHODS Axial length measurements in 50 cataractous eyes were obtained by optical biometry (IOLMaster, Zeiss Humphrey Systems) and immersion ultrasound (Axis II, Quantel Medical), and the results were compared. Intraocular lens (IOL) power calculations in the same eyes after cataract extraction and posterior chamber IOL implantation were evaluated retrospectively based on the postoperative spherical equivalent prediction error. RESULTS Immersion ultrasonography and partial coherence interferometry measurements correlated in a highly positive manner (correlation coefficient = 0.996). Outcomes analysis demonstrated 92.0% of eyes were within +/-0.5 diopter of emmetropia based on immersion axial length measurements. CONCLUSION Immersion ultrasonography provided highly accurate axial length measurements and permitted highly accurate IOL power calculations.
منابع مشابه
تکرارپذیری و میزان تشابه اندازهگیریهای بیومتری توسط دستگاه swept source optical coherence (OA2000) و partial coherence interferometry (IOL Master) به عنوان مرجع
هدف: بررسی تکرارپذیری و میزان تشابه اندازهگیری پارامترهای ضخامت لنز (Lens Thickness, LT)، عمق اتاق قدامی (Anterior Chamber Depth, ACD)، طول محوری (Axial Length, AL) و کراتومتری (Keratometry, K) توسط دستگاه جدید ۲۰۰۰OA- و مقایسه آن با دستگاه ۵۰۰IOL Master. روش پژوهش: در این مطالعه مقطعی، بیماران دارای کاتاراکت در یک یا دو چشم برای ورود به مطالعه انتخاب شدند. پارامترهایAL, ACD, LT, K توسط دستگاه...
متن کاملThe Relationship between English and Persian Phonological Awareness, Rapid Autamatized Naming and Students’ Reading Achievement in Partial Immersion and Non-Immersion Programs
The cognitive predictors (i.e.,Phonological Awareness, and Rapid Automatized Naming) underlying reading achievement have not been researched in Iranian partial English immersion and non-immersion programs. The present study sought to investigate the relationship between English and Persian Phonological Awareness (PA), Rapid Autamatized Naming (RAN) and reading achievementof Iranian students in ...
متن کاملEstimation of Earthquake Damage Through Radar Interferometry (Case study: Bam 2003 Earthquake)
The estimate of the damage caused by the earthquake and other natural disasters in the first days after the occurrence of these events can provide a quick damages assessment and help to manage the crisis. Several methods are available to investigate the extent of earthquake’s damage. Optical remote sensing, photogrammetric methods (UAVs and LIDARs), radar interferometry (InSAR) and field observ...
متن کاملAngular light scattering studies using low-coherence interferometry
A modified Michelson interferometer is used to measure path-length resolved angular distributions of light backscattered by turbid media. The path length resolution is obtained by exploiting the coherence properties of a broadband source. The angular distribution is mapped out using a simple optical system to scan the angle at which the reference field intersects the detector plane. Angular sca...
متن کاملPartial Coherence Laser Interferometry in Highly Myopic versus Emmetropic Eyes
PURPOSE To investigate the reliability of partial coherence laser interferometry for optical biometry in highly myopic eyes. METHODS Axial length measurements by the IOLMaster (Carl Zeiss Meditec, Germany) with signal-to-noise ratio (SNR) ≥2 were performed in 52 consecutive myopic subjects with axial length ≥26.5 mm and 45 emmetropic patients before cataract surgery. Axial length measurements...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of cataract and refractive surgery
دوره 28 2 شماره
صفحات -
تاریخ انتشار 2002