Pediatric evaluation of the bispectral index (BIS) monitor and correlation of BIS with end-tidal sevoflurane concentration in infants and children.
نویسندگان
چکیده
UNLABELLED The bispectral index (BIS) has been developed in adults and correlates well with clinical hypnotic effects of anesthetics. We investigated whether BIS reflects clinical markers of hypnosis and demonstrates agent dose-responsiveness in infants and children. In an observational arm of this study, BIS values in children undergoing general anesthesia were observed and compared with similar data collected previously in a study of adults. In a second arm of the study, a range of steady-state end-tidal concentrations of sevoflurane was administered and corresponding BIS documented. Data were examined for differences between infants (0-2 yr) and children (2-12 yr). No difference was seen in BIS values in children before induction, during maintenance, and on emergence compared with adult values. There was no difference in BIS between infants and children at similar clinical levels of anesthesia. In children and infants, BIS was inversely proportional to the end-tidal concentration of sevoflurane. The sevoflurane concentration for a BIS = 50 (95% confidence interval) was significantly different: 1. 55% (1.40-1.70) for infants versus 1.25% (1.12-1.37) for children. Although validation with specific behavioral end points was not possible, BIS correlated with clinical indicators of anesthesia in children as it did in adults: as depth of anesthesia increased, BIS diminished. BIS correlated with sevoflurane concentration in infants and children. The concentration-response difference between infants and children was consistent with data showing that minimum alveolar concentration is higher in children less than 1 yr of age. IMPLICATIONS The use of bispectral index (BIS) during general anesthesia improves the titration of anesthetics in adults. The data from this study suggest that the same equipment and method of electroencephalogram analysis may be applied to infants and children.
منابع مشابه
Correlation of bispectral index with end-tidal sevoflurane concentration and age in infants and children.
BACKGROUND The bispectral index (BIS) has been evaluated as a tool for measuring depth of anaesthesia, but the use of BIS in a paediatric population is still controversial. This study was designed to evaluate the correlation of BIS with end-tidal sevoflurane concentration and age in infants and children. METHODS Eighty-one patients undergoing elective urology surgery were allocated into three...
متن کاملSpectral entropy as a measure of hypnosis in children.
BACKGROUND The Datex-Ohmeda S/5 Entropy Module (Datex-Ohmeda Division, Instrumentarium Corp., Helsinki, Finland), using time-frequency balanced Spectral Entropy, is a novel tool for monitoring the hypnotic state during anesthesia. The Entropy Module produces two values, State Entropy (SE) and Response Entropy (RE), and in adults, it has been shown to measure reliably the hypnotic effects of var...
متن کاملEvaluation of the Adequacy of General Anesthesia in Cesarean Section by Bispectral Index
Background: Awareness and recall, though not common, are the major hazards of general anesthesia, especially in Cesarean section (C/S) because of the absence of benzodiazepine and opioids for a significant time during anesthesia. In this study, the Bispectral Index (BIS), end-tidal isoflurane, and hemodynamic parameters were examined to evaluate the depth of the routine general anesthetic techn...
متن کاملThe bispectral index system in pediatrics--is it related to the end-tidal concentration of inhalation anesthetics?
UNLABELLED BACKGROUND AND GOAL OF STUDY: Bispectral Index (BIS) has been used in adults to measure depth of anesthesia using various protocols. Though less investigated in children, there is growing evidence that bispectral index seems adequately calibrated for monitoring the depth of isoflurane and sevoflurane anesthesia in pediatric patients. A range of BIS scores (40-60) has been seen to be ...
متن کاملThe dynamic relationship between end-tidal sevoflurane concentrations, bispectral index, and cerebral state index in children.
BACKGROUND To guide anesthetic administration with electroencephalogram monitors in children, an adequate characterization of the anesthetic effect measured by these monitors in this population is needed. We sought to quantify and compare the dynamic profile of sevoflurane's effect measured with the cerebral state index (CSI) and the bispectral index (BIS) in children. METHODS Fifteen healthy...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Anesthesia and analgesia
دوره 90 4 شماره
صفحات -
تاریخ انتشار 2000