Applicability of segmental bioelectrical impedance analysis for predicting trunk skeletal muscle volume.
نویسندگان
چکیده
This study aimed to investigate the validity of using segmental bioelectrical impedance (BI) analysis for estimating skeletal muscle volume (MV) in the trunk, defined as the body segment from the acromion process to the greater trochanter. Using a magnetic resonance imaging (MRI) method, the trunk MV was determined in 28 men (19 approximately 34 yr), divided into validation (n = 20) and cross-validation (n = 8) groups, and used as a reference (MV(MRI)). For BI measurements of the trunk, the source electrodes were placed at the dorsal surface of the third metacarpal bone of both hands and the dorsal surface of the third metatarsal bone of both feet, and the detector electrodes were placed at the acromion process of both shoulders and the greater trochanter of both femurs. Using this arrangement, the BI values of five parts of the trunk, both sides of the upper region, the middle region, and both sides of the lower region, were obtained and then used to calculate the whole trunk BI value and BI index (BI index(TR)). In the validation group, a simple regression analysis of the relationship between BI index(TR) and MV(MRI) showed a significant correlation between the two variables (r = 0.884, P < 0.05) and produced a prediction equation with a SE of estimation of 1,020.3 cm3 (8.5%). In the validation and cross-validation groups, there were no significant differences between the measured and estimated MV without systematic errors. These findings indicate that the segmental BI analysis employed in the present study can be used to estimate trunk MV.
منابع مشابه
Applicability of a segmental bioelectrical impedance analysis for predicting the whole body skeletal muscle volume.
This study aimed to test the hypothesis that a segmental bioelectrical impedance (BI) analysis can predict whole body skeletal muscle (SM) volume more accurately than a whole body BI analysis. Thirty males (19-34 yr) participated in this study. They were divided into validation (n = 20) and cross-validation groups (n = 10). The BI values were obtained using two methods: whole body BI analysis, ...
متن کاملComparison of Muscle Mass, Total Body Water and Total Body Protein in Type II Diabetics with Healthy Matched Adults by Bioelectrical Impedance Analysis
Background: Bioelectrical impedance analysis (BIA) is a new and rapid technique to validate body composition. Several studies have used this technique to evaluate body compositions, such as muscle mass, in diabetic patients, but the results are very different. This may due the differences between diabetic patients and control group. Therefore, this study aimed to compare the muscle mass of diab...
متن کاملComparison of single- or multifrequency bioelectrical impedance analysis and spectroscopy for assessment of appendicular skeletal muscle in the elderly.
Bioelectrical impedance analysis (BIA) is used to assess skeletal muscle mass, although its application in the elderly has not been fully established. Several BIA modalities are available: single-frequency BIA (SFBIA), multifrequency BIA (MFBIA), and bioelectrical impedance spectroscopy (BIS). The aim of this study was to examine the difference between SFBIA, MFBIA, and BIS for assessment of ap...
متن کاملSegmental body composition assessed by bioelectrical impedance analysis and DEXA in humans.
The present study assessed the relative contribution of each body segment to whole body fat-free mass (FFM) and impedance and explored the use of segmental bioelectrical impedance analysis to estimate segmental tissue composition. Multiple frequencies of whole body and segmental impedances were measured in 51 normal and overweight women. Segmental tissue composition was independently assessed b...
متن کاملComparison of Total Fat, Percentage of Fat, Trunk Fat, Soft Lean and Mass Waist-Hip Ratio between Diabetic type II and Matched Non-Diabetic Iranians using Bioelectrical Impedance Analysis
Introduction: Research shows a relationship between diabetes (type II) and obesity. Bioelectrical Impedance Analysis (BIA) is a relatively new and approved method for the measurement of body composition. The aim of this study was to compare diabetic and non-diabetic adults on the basis of waist-hip ratio, total fat, percentage of fat, trunk fat, and soft lean mass. Methods: In this cross-sec...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of applied physiology
دوره 100 2 شماره
صفحات -
تاریخ انتشار 2006