MultiFrequency Trans-Admittance Scanner: Mathematical Framework and Feasibility

نویسندگان

  • Sungwhan Kim
  • Jeehyun Lee
  • Jin Keun Seo
  • Eung Je Woo
  • Habib Zribi
چکیده

A trans-admittance scanner (TAS) is a device for breast cancer diagnosis based on numerous experimental findings that complex conductivities of breast tumors significantly differ from those of surrounding normal tissues. In TAS, we apply a sinusoidal voltage between a handheld electrode and a scanning probe placed on the breast skin to make current travel through the breast. The scanning probe has an array of electrodes at zero voltage. We measure exit currents (Neumann data) through the electrodes that provide a map of trans-admittance data over the breast surface. The inverse problem of TAS is to detect a suspicious abnormality underneath the breast skin from the measured Neumann data. Previous anomaly detection methods used the difference between the measured Neumann data and a reference Neumann data obtained beforehand in the absence of anomaly. However, in practice, the reference data is not available and its computation is not possible since the inhomogeneous complex conductivity of the normal breast is unknown. To deal with this problem, we propose a frequency-difference TAS (fdTAS), in which a weighted frequency difference of the trans-admittance data measured at a certain moment is used for anomaly detection. This paper provides a mathematical framework and the feasibility of fdTAS by showing the relationship between the anomaly information and the weighted frequency difference of the Neumann data.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A New Trans-admittance-Mode Biquad Filter Suitable for Low Voltage Operation

The trans-admittance-mode (TAM) might act as a transforming bridge for voltage-mode to current-mode conversion. In this study a new low voltage operated electronically tunable TAM biquad filter structure realizing all the seven standard filtering functions namely; low-pass (LP), band-pass (BP), high-pass (HP), regular-notch (RN), low-pass-notch (LPN), high-pass-notch (HPN) and all-pass (AP) fro...

متن کامل

Multifrequency tympanometry and evoked otoacoustic emissions in neonates during the first 24 hours of life.

Multifrequency, complex-component tympanograms and transient evoked otoacoustic emissions (EOAEs) were recorded in 55 neonates less than 24 hours of age. The purpose of the investigation was to determine the normal middle ear immittance characteristics of neonates less than 24 hours old (the approximate discharge age of well-babies) and to assess whether an association exists between transient ...

متن کامل

Normative multifrequency tympanometry in infants and toddlers.

Multifrequency tympanometry data were measured multiple times between the ages of four weeks and two years from 33 infants/toddlers. Tympanograms were also measured from 33 adult participants. Tympanograms recorded with five probe-tone frequencies (226, 400, 630, 800, and 1000 Hz) were classified using the Vanhuyse et al model classification system (Vanhuyse et al, 1975). Admittance at +200 daP...

متن کامل

Admittance mode framework for haptic teleoperation of hovering vehicles with unlimited workspace

This paper discusses a new approach to haptic feedback for teleoperation of hovering vehicles. Traditionally airplane and helicopter controls use the displacement of a joystick as the main supervisory control input. It is common to overlay force feedback to convey additional information about forces occuring in the controlled craft. However, there are some fundamental problems when trying to fe...

متن کامل

Standard and multifrequency tympanometry in normal and otosclerotic ears.

OBJECTIVES The primary goal of this study was to evaluate alternative tympanometric parameters for distinguishing normal middle ears from ears with otosclerosis. A secondary goal was to provide guidelines and normative data for interpreting multifrequency tympanometry obtained using the Virtual 310 immittance system. DESIGN Nine tympanometric measures were examined in 68 normal ears and 14 ea...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • SIAM Journal of Applied Mathematics

دوره 69  شماره 

صفحات  -

تاریخ انتشار 2008